27
CLEARSPAN
™
STORAGE MASTER
Revision date: 05.08.19
END FRAMING CONNECTIONS
Position this header tube as needed if installing a pedestrian door
.
Splice the 2" x 2" tubes using a 104075 insert and Tek screws.
2" x 2"
2" x 2"
104075
Tek Screws
Secure the band clamp to the rafter as shown.
Tek Screw
QH1330
ATTENTION:
The spacing show above may dif
fer from the spacing of the actual end wall.
The spacing of the
individual end frame members and the size of the door opening depends on the door
. If doors are to be installed,
frame the end wall as needed to accommodate the door or doors. (Additional parts may be required for door installation.)
The verticals installed above and below the door header are installed slightly of
f-centered to avoid conflicts with
the hardware attached to the end rafter for the main frame of the shelter
. Position these as needed to avoid
frame component conflicts.
Ground Level
Splice the 2" x 2" tubes using a 104075 insert and Tek screws.
Install T
ek
screws along this edge of the door frame.
Install T
ek
screws along this edge to splice the frame joint.
10' inside-to-inside
(width)
9' inside- to-inside (height)
See Door Jamb
Addendum