33
Clear-Com HME DX210 System Guide
Syncing Secondary to Primary Bases Feature
To sync the bases, perform the following steps: Press the
REG
or
REGISTER BELT-PAC*
button on the primary base
and then press the
REG
or
REGISTER BELT-PAC*
button on the secondary base to begin the sync process. As you
repeatedly press the
REG
or
REGISTER BELT-PAC*
button on the secondary
you will see the numbers 1, 2, and 3
cycle through on the display. The numbers indicate the three available quadrants.
Note: The primary is in the 0
quadrant by default.
To select a quadrant simply release the button at a desired number and wait. If successful, you will
briefly see a blank display followed by a single horizontal bar in the secondary LED display. For additional secondary
bases, assign each base to its own quadrant. Refer to the appropriate equipment manual for primary to secondary
conversion.
After the bases are synced when the secondary is powered up the number “8” will appear followed by one of the numbers
below on the secondary base LED display:
The number “1” indicates the quadrant the secondary has been placed in.
The number “2” indicates the quadrant the secondary has been placed in.
The number “3” indicates the quadrant the secondary has been placed in.
The lower case “c” will appear when the registry on the base station is cleared. To clear the registry
power down the base. Hold down the
CLR/BND
or
RESET REGISTRATION*
button first and then
power the base on when you see the “8” on the LED display release the
CLR/BND
or
RESET
REGISTRATION*
. If done successfully you will see a small "c" on the LED display.
NOTE: The
display indicates that the registry of a base station has been cleared of all beltpacks and secondary
base stations that were registered to the base station.
Another method to clear the registry would be to start by holding down the
CLR/BND
or
RESET REGISTRATION*
button first and then pressing the
RESET
button until you hear a small click and then release the
CLR/BND
or
RESET
REGISTRATION*
button. If done successfully you will see a small "c" on the LED display. We recommend you use a
very small paper clip.
The lower case “o” will appear when the
REG
or
REGISTER BELT-PAC*
button is pressed and
indicates that the base is ready to register a beltpac.
When registering beltpacks on DX bases that can carry 15 beltpacks please note that the numeric count displayed on the
LED will be in hexadecimal. This means that the LED will represent the first 10 beltpacks as 0 to 9. Beltpac 11 will be
represented by the letter A, beltpac 12 will be represented by the letter B and on up to beltpac 15 as E. Please see below.
Beltpac or Headset
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Registry
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E