6
Clear-Com HME DX210 Operating Instructions
2.1.3 Connect AC50 Power Supply
To connect the AC power supply to the battery charger:
1. Connect the AC power supply cable connector to the power connection on the battery charger.
2. Connect the AC power cord to an electrical outlet.
The red lights on the charger will briefly display, and then the yellow lights will appear and remain on.
2.1.4 Charge Batteries
Up to four batteries can be charged in the battery charger at one time. The battery status lights next to
each charging port indicate the battery status. Up to four fully charged batteries can be stored in the
battery Storage ports. Insert a battery in each of four Charging ports until it clicks in place.
A yellow light next to a Charging port indicates that the port is
EMPTY
.
A red light next indicates that the battery port is
CHARGING
.
A green light indicates that the battery is
READY
.
A steady yellow light indicates that the
CHARGE FAILED
. If a charge fails, refer to the
instructions on the side of battery charger.
A flashing yellow light next indicates
CHARGE PENDING
, which means the inserted battery is
too hot. Adjust the room temperature or move the charger to a cooler area.
Store fully charged batteries in storage ports.
IMPORTANT:
Batteries should not be left in charge ports after being fully charged. A battery left in a
charging port for more than three weeks may display the yellow indicator light, but it does not indicate a
faulty battery.