background image

12

DWP - 1106 A | Version 1.03

Disposal, recycling of used devices

Clean all plastic parts and painted surfaces with a soft, 
damp cloth and a little neutral cleaner. 

If necessary, clean the suction slots of the suction foot 
with clear water. 

The pump requires water for lubrication and must never 
run dry.

Cleaning the filter

As soon as the pump water is no longer perfectly clean, it 
may be necessary to clean the filter and suction area 
(11, Fig.4). Use a steel brush to remove the accumulated 
dirt.

It is also possible to clean the inner part. To do this, loo-
sen the screws (11, fig.4) that fix the filter to the pump 
body and remove it. Use a steel brush to remove the dirt. 
Finally, rinse the cleaned parts with clean water, put the 
filter back in the pump body and tighten the screws. 

Fig. 4:  Cleaning the filter

Inspection of the rope

- Pull the pump out of the sump from time to time.

- Check rope. If the rope is damaged, replace it with 

an original spare part.

- Check that the rope lugs on the pump are still able 

to bear the load.

If the rope is damaged, you can try to pull the pump care-
fully out of the sump by the discharge line. Never pull on 
the power cable.

11.2

Maintenance and repair

Maintenance and repair work may only be carried out by 
qualified personnel.

Maintenance and repair work may only be carried out by 
qualified personnel.

If the water pump does not work properly, contact a de-
aler or our customer service. The contact details can be 
found in chapter 1.2 Customer Service.

All protection and safety equipment must be reinstalled 
immediately after completion of repair and maintenance 
work.

Make sure the pump is off before performing any main-
tenance or repair.

Regular maintenance and careful care reduce the risk of pos-
sible malfunctions and help extend the life of your device. 

12 Disposal, recycling of used 

devices

Please take care in your own interest and in the interest of 
the environment that all component parts of the ma-chine 
are only disposed of in the intended and permitted way. 

12.1Decommission

Discarded devices must be taken out of operation imme-
diately in a professional manner in order to avoid later 
misuse and danger to the environment or persons.

- Remove all environmentally hazardous operating mate-

rials from the old device.

- The disassembly of the water pump must be carried out 

by a trained, professional specialist. 

- Dispose of the machine components and operating 

fluids in the appropriate disposal route.

12.2Disposal of electrical equipment

Please note that electrical equipment contains a large 
number of recyclable materials and environmentally 
harmful components. 

Please help to ensure that these components are sepa-
rated and disposed of properly. In case of doubt, please 
contact your local waste disposal service. 

If necessary, use the services of a specialized waste dis-
posal company for processing.

12.3Disposal of lubricants

Please make sure that the coolants and lubricants used 
are disposed of in an environmentally friendly manner. 
Observe the disposal instructions of your municipal wa-
ste disposal company. The lubricant manufacturer provi-
des the disposal instructions for the lubricants used. If 
necessary, ask for the product-specific data sheets.

DANGER!

Maintenance and repairs must always be carried out 
by qualified personnel; any damaged parts must only 
be replaced by original spare parts.

Summary of Contents for 7523105

Page 1: ...DWP 1106 A Deep well pump Instruction Manual DWP 1106 A DWP 1106 A...

Page 2: ...2 Safety 3 2 1 Symbol explanation 3 2 2 Obligations of the operating company 4 2 3 Requirements to staff 5 2 4 Personal protective equipment 5 2 5 General safety regulations 5 2 6 Safety markings on t...

Page 3: ...gained from using the application which then could be shared and be valuable to develop our products even further 1 3 Limitation of liability All information and notes in these operating instructions...

Page 4: ...pond to the current status of the regulations and must adapt these if necessary The operating company must unambiguously regu late and determine the responsibilities for installa tion operation troubl...

Page 5: ...against impairments of safety and health while wor king The staff member has to wear personal protective equipment while performing different tasks on and with the machine which are indicated in the i...

Page 6: ...laced immediately From the time when the signs are not immediately recog nisable and understandable at first sight the machine must be taken out of operation until the new signs are at tached DANGER A...

Page 7: ...components can lead to burns and other injuries Risk of damage due to absorption of unsuitable liquids Electrical hazard due to contact with parts and high voltage direct contact or with parts that ar...

Page 8: ...and frost free environment Water pumps must not be stacked on top of each other Nor may other objects be placed on top of it Step 1 Switch off the water pump and empty it completely Step 2 Wipe all a...

Page 9: ...n cords that are designed for out door use If the power cord needs to be extended use only a cable type H07RN F 9 Commissioning NOTE When operating the pump outdoors the electrical connections must be...

Page 10: ...ter pump DANGER The device must be correctly installed before use It must also be checked that the filter elements are cor rectly mounted and efficient The unit should only be operated assembled repai...

Page 11: ...ng up the pump for the first time it is essential to ensure that the pump housing is com pletely vented even with self priming pumps If this venting is not carried out the pump does not suck in the pu...

Page 12: ...r and maintenance work Make sure the pump is off before performing any main tenance or repair Regular maintenance and careful care reduce the risk of pos sible malfunctions and help extend the life of...

Page 13: ...p you with your problem in the best possible way Model name of the device Serial number of the device Construction year Exact error description Fault Possible cause Remedy Engine will not start 1 No e...

Page 14: ...item No and year of manufacture on the type plate fixed to the Water pump Example The engine for the Deep well pump DWP 1106 A must be ordered The engine has the number 49 in the spare parts drawing...

Page 15: ...arts drawing DWP 1106 A The following drawing should help you to identify necessary spare parts in case of service If necessary send a copy of the parts drawing with the marked components to your auth...

Page 16: ...16 DWP 1106 A Version 1 03 Circuit diagram DWP 1106 A 15 Circuit diagram DWP 1106 A Fig 6 Circuit diagram DWP 1106 A...

Page 17: ...imilar apparatus with regard to human exposure DIN EN 60335 1 2012 Household and similar electrical appliances Safety Part 1 General requirements DIN EN 60335 2 41 2003 A1 A2 Household and similar ele...

Page 18: ...www cleancraft de...

Reviews: