Safety

-Wear appropriate protective clothing and goggles when 

installing the water pump.

- Before each use make sure that no parts of the water 

pump are damaged. Damaged parts must be replaced 
immediately to avoid sources of danger.

- Do not overload the water pump! You will work better 

and safer in the specified performance range. 

- Do not use the pump in hazardous areas or near flam-

mable liquids and gases.

- Do not touch the mains plug with wet hands.

- Seal all screw connections with a thread sealing tape to 

prevent water from leaking.

- Do not let the pump run dry.

- Never let the submersible pump run against a closed 

pressure line.

- Only disassemble the pump body when the pump is 

switched off and the pump chamber is empty.

- Only use original spare parts and accessories to avoid 

possible dangers and risks of accidents.

- Only install the water pump while it is switched off.

- Stürmer Maschinen GmbH accepts no liability for de-

sign and technical modifications to the water pump.

.

2.6 Safety markings on the water pump

Safety markings and instructions are attached to the wa-
ter pump (Fig. 1), which must be observed and followed.
 

Fig. 1:  Safety labels

Damaged or missing safety symbols on the water pump 
can lead to incorrect handling with personal injury and 
damage to property. The safety symbols attached to the 
machine must not be removed. 

Damaged safety symbols must be replaced immediately. 
From the time when the signs are not immediately recog-
nisable and understandable at first sight, the machine 
must be taken out of operation until the new signs are at-
tached. 

DANGER!

Any modification of the device is prohibited. In addi-
tion to invalidating the warranty, the modification may 
result in fire and injury, including death, to the user.                                                  
The manufacturer accepts no liability for damage to 
property or persons as a result of failure to follow 
these instructions or misuse of the unit. 

DANGER!

Do not pump salt water with the pump!

DANGER!

The water pump must not be used to pump food.

DANGER!

If the ambient temperature is lower than 5°C or the 
pump is not used for a longer period of time, drain 
the piping system to avoid ice formation in the pump 
chamber.

DANGER!

The pumped liquid may be hot and under high pressure. 
Before moving or disassembling the pump, empty the 
liquid in the pump and piping to avoid scalding.

DANGER!

Check that the supply voltage of the water pump cor-
responds to the water pump nameplate. Failure to 
observe these rules may result in fire and injury, 
including death, to the user.

DANGER!

The pump is not suitable for pumping salt water, 
faeces, flammable, corrosive, explosive or other dan-
gerous liquids. The pumped liquid must not exceed 
or fall below the maximum or minimum temperature 
specified in the technical data. 

DANGER!

When pumping dirty liquids, install a suction strainer 
to protect the pump from dirt.

DANGER!

If no water is delivered after 5 minutes of operation of 
the water pump, switch off the pump, refill water and 
check the pipes for leaks. 

Summary of Contents for 7523105

Page 1: ...DWP 1106 A Deep well pump Instruction Manual DWP 1106 A DWP 1106 A...

Page 2: ...2 Safety 3 2 1 Symbol explanation 3 2 2 Obligations of the operating company 4 2 3 Requirements to staff 5 2 4 Personal protective equipment 5 2 5 General safety regulations 5 2 6 Safety markings on t...

Page 3: ...gained from using the application which then could be shared and be valuable to develop our products even further 1 3 Limitation of liability All information and notes in these operating instructions...

Page 4: ...pond to the current status of the regulations and must adapt these if necessary The operating company must unambiguously regu late and determine the responsibilities for installa tion operation troubl...

Page 5: ...against impairments of safety and health while wor king The staff member has to wear personal protective equipment while performing different tasks on and with the machine which are indicated in the i...

Page 6: ...laced immediately From the time when the signs are not immediately recog nisable and understandable at first sight the machine must be taken out of operation until the new signs are at tached DANGER A...

Page 7: ...components can lead to burns and other injuries Risk of damage due to absorption of unsuitable liquids Electrical hazard due to contact with parts and high voltage direct contact or with parts that ar...

Page 8: ...and frost free environment Water pumps must not be stacked on top of each other Nor may other objects be placed on top of it Step 1 Switch off the water pump and empty it completely Step 2 Wipe all a...

Page 9: ...n cords that are designed for out door use If the power cord needs to be extended use only a cable type H07RN F 9 Commissioning NOTE When operating the pump outdoors the electrical connections must be...

Page 10: ...ter pump DANGER The device must be correctly installed before use It must also be checked that the filter elements are cor rectly mounted and efficient The unit should only be operated assembled repai...

Page 11: ...ng up the pump for the first time it is essential to ensure that the pump housing is com pletely vented even with self priming pumps If this venting is not carried out the pump does not suck in the pu...

Page 12: ...r and maintenance work Make sure the pump is off before performing any main tenance or repair Regular maintenance and careful care reduce the risk of pos sible malfunctions and help extend the life of...

Page 13: ...p you with your problem in the best possible way Model name of the device Serial number of the device Construction year Exact error description Fault Possible cause Remedy Engine will not start 1 No e...

Page 14: ...item No and year of manufacture on the type plate fixed to the Water pump Example The engine for the Deep well pump DWP 1106 A must be ordered The engine has the number 49 in the spare parts drawing...

Page 15: ...arts drawing DWP 1106 A The following drawing should help you to identify necessary spare parts in case of service If necessary send a copy of the parts drawing with the marked components to your auth...

Page 16: ...16 DWP 1106 A Version 1 03 Circuit diagram DWP 1106 A 15 Circuit diagram DWP 1106 A Fig 6 Circuit diagram DWP 1106 A...

Page 17: ...imilar apparatus with regard to human exposure DIN EN 60335 1 2012 Household and similar electrical appliances Safety Part 1 General requirements DIN EN 60335 2 41 2003 A1 A2 Household and similar ele...

Page 18: ...www cleancraft de...

Reviews: