APPENDIX A
52
Domestic Hot Water Coil Installation:
(1) Refer
to
Figure
A2.
(2) Remove the six nuts and bolts holding the cover in position.
(3) Carefully slide the domestic hot water coil, with the rubber gasket in place, into the tube.
(4) Tighten the hot water coil in postion with the six nuts and bolts.
Figure A2: Domestic Hot Water Coil Location
CE70098
REMOVE COVER AND
INSERT DOMESTIC
HOT WATER COIL
DANGER:
Mixing valves must be used to supply domestic hot water at a safe
temperature. Mixing valves are not intended to be the only scalding safe-guard.
Summary of Contents for CE-340
Page 2: ...7 3 13 Part 70006 Underwriters Laboratories File MH48829 ...
Page 35: ...BOILER DIMENSIONS 35 57 5 42 5 67 with Burner 34 0 CE70077 50 ...
Page 40: ...40 1 4 12 6 15 9 10 14 3 2 11 5 13 8 7 Nozzle Adapter Heater Block Assembly ...