10
Installing the Connector Block and Oil Line:
(1) Refer to Figure 7 to position the connector block.
(2) Fasten the connector block to the side of the boiler
with the bolts provided.
(3) Install the supplied 3/8” copper tubing from the swivel
fitting in the connector block to the burner.
NOTICE:
The connector block with the swivel fitting
must be used to allow the front door to swing open
properly. If the connector block is not used the oil line will
need to be disconnected before the door is opened.
Figure 7: Installing the Connector Block and Oil Line
Figure 6: Installing the Burner Cord
(4) Refer to Figure 6
(5) Line up the key in the receptacle with the slot in the
cord.
(6) Tighten the electrical cord when in position.
NOTICE:
Make sure the plug and receptacle are
properly aligned. The ground prong in the receptacle
is longer than the other prongs and must be lined up
properly.
BOILER ASSEMBLY
WARNING:
To prevent the risk of electrical
shock, shut OFF main power to the boiler before
connecting or disconnecting the burner power
cord.
CE70013
CE70085
Oil Line
Connector Block
Summary of Contents for CE-340