background image

WARRANTY

IO-DV090

IO-DV090

WWW.CLEANCOMFORT.COM

18

Limited Warranty

Daikin North America LLC (“Daikin”) warrants as follows: the 

Clean Comfort dehumidifier (“Product”) will be free of material 

defects in workmanship or materials for a period of five (5) 

years following the date of purchase of such Product by the 

original consumer purchaser (“Customer”). Some states and 

provinces do not allow limitation of warranty coverage to the 

original consumer, so the above limitation may not apply to you.

Limitation of Liability.

 

Customer’s sole and exclusive remedy 

under the above limited warranty, and any implied warranties, 

and Daikin’s entire liability thereunder, shall be for Daikin to 

provide a repaired or replacement Product or component of 

the Product (“Component(s)”), at the sole option of Daikin. 

Refrigerant, piping, supplies, transportation costs, labor costs 

incurred in deinstalling any defective Product or Components,  

or installing the repaired or replacement Product or 

Components, are not included. This disclaimer and exclusion 

shall apply even if the express warranty herein fails of 

its essential purpose. Customer acknowledges that no 

representative of Daikin or any of its affiliates or resellers is 

authorized to make any representation or warranty on behalf 

of Daikin or any of its affiliates or resellers that is not in this 

warranty. IN NO EVENT SHALL DAIKIN, IN CONNECTION WITH 

THE DESIGN, SALE, INSTALLATION, USE, REPAIR, REPLACEMENT 

OR PERFORMANCE OF ANY PRODUCT OR COMPONENTS, 

OR WRITTEN MATERIAL PROVIDED THEREWITH, BE LIABLE, 

WHETHER FOR BREACH OF WARRANTY OR OTHER CONTRACT 

BREACH, NEGLIGENCE OR OTHER TORT, OR ON ANY OTHER 

LEGAL THEORY, FOR ANY SPECIAL, INDIRECT, COLLATERAL OR 

CONSEQUENTIAL DAMAGES OF ANY KIND. Some states and 

provinces do not allow the exclusion or limitation of incidental 

or consequential damages, so the above exclusion may not 

apply to you.

Other Warranties.

 THE ABOVE LIMITED WARRANTY IS THE  

SOLE AND EXCLUSIVE EXPRESS WARRANTY PROVIDED WITH 

RESPECT TO THE PRODUCT AND ITS COMPONENTS, AND 

DAIKIN HEREBY LIMITS THE DURATION OF ALL IMPLIED 

WARRANTIES, INCLUDING, WITHOUT LIMITATION, THE IMPLIED 

WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A 

PARTICULAR PURPOSE, TO THE DURATION OF THE ABOVE 

LIMITED WARRANTY. Some states and provinces do not allow 

exclusion of express warranties and/or limitations on how 

long an implied warranty lasts, so the above exclusion and/or 

limitation may not apply to you.

Warranty Limitations.

 The foregoing limited warranty 

extends only to a Customer, and the Customer will not be 

entitled to any remedy hereunder if he or she attempts to 

assign or transfer this warranty. A “defect” under the terms of 

this limited warranty shall not include problems resulting from 

Customer’s or Customer’s employees’, agents’, invitees’ or a 

third party’s misuse, improper installation, improper design 

of any system in which the Product is included, abuse, lack of 

normal care, failure to follow written instructions, tampering, 

improper repair, or freezing, corrosion, acts of nature or other 

causes not arising out of defects in workmanship or material. 

If a Product or Component is replaced while under warranty, 

the applicable limited warranty period shall not be extended 

beyond the warranty time period remaining on the original 

Product or Component. This limited warranty does not cover 

any costs related to changes to a Product or Component that 

may be required by any codes, laws, or regulations that may 

become effective after initial purchase of the Product by 

Customer.

Customer Responsibilities.

 In order to make a warranty  

claim, the Customer should call Daikin Consumer Affairs 

at 1-855-239-2665, which will then arrange for Product or 

Component repair or replacement. Warranty claims must be 

made during customary, daytime working hours. As further 

conditions to obtaining warranty coverage hereunder, the 

Customer must present forms of invoices evidencing proof of 

purchase of a Product and return the Product to Daikin if Daikin 

so requests. If the invoice presented does not clearly indicate 

the date of initial purchase by a Customer, the applicable 

Product’s date of manufacture shown on the Product’s rating 

plate will be used instead of the date of initial purchase 

for the purpose of calculating the commencement of the 

applicable warranty period. Repaired or replacement Products 

or Components must be provided by Daikin or a servicer 

authorized by Daikin. If the Product must be shipped to Daikin, 

Customer shall be solely responsible for properly packaging the 

Product, for all freight charges, and for all risk of loss associated 

with shipment. 

Miscellaneous.

 If any term or condition of this Limited 

Warranty is found by a court of competent jurisdiction to be 

invalid, illegal or otherwise unenforceable, the same shall not 

affect the other terms or conditions hereof or thereof or the 

whole of this Limited Warranty. Any delay or failure by Daikin 

to exercise any right or remedy will not constitute a waiver of 

Daikin to thereafter enforce such rights.

This warranty gives you specific legal rights, and you may  

also have other rights which vary from state to state or  

province to province.

DAIKIN NORTH AMERICA LLC

4201 Lien Rd.  

Madison, Wisconsin 53704

1-855-239-2665

For questions regarding warranty, service, or spare  
parts for this Clean Comfort product please contact  
your installing contractor or a local Daikin representative.  
For technical support, please call 1-855-239-2665.

Summary of Contents for DV090

Page 1: ...l the incoming air stream below its dew point This cooled and drier air is used to pre cool the incoming air stream resulting in increased overall efficiency After the pre cooling stage the processed air is reheated by passing through the condenser coil Fresh Air Ventilation Optional Fresh outdoor air may be ducted to the dehumidifier This provides fresh air to dilute indoor pollutants and repleni...

Page 2: ... Daikin North America LLC All rights reserved INTRODUCTION 1 SAFETY PRECAUTIONS 3 INTENDED APPLICATION 3 REGISTRATIONS 3 OPTIONAL PARTS LIST 3 SPECIFICATIONS 3 INSTALLATION 3 Installation Considerations 4 Power Accessibility 4 Space 4 Low Voltage Wiring 4 Back Draft Damper 4 Support Structure and Suspension 4 Electrical Requirements 4 Condensate Water Removal 5 Lifting Condensate 5 Condensate Pump...

Page 3: ...apacity 90 Pints Day 43 L Day Efficiency 5 3 pints kWhr 2 5 L kWhr Duct Connections 6 Round Inlet 10 Round Inlet 10 Round Outlet Air Filter Efficiency MERV 11 Standard 65 Efficient ASHRAE Dust Spot Test Size 14 X 14 x1 Power Cord 8 ft 2 4 m Drain Connection 3 4 Threaded FNPT Refrigerant Type R410a Refer to manufacturers label for more information Dimensions Unit Shipping Width 15 39 cm 18 47 cm He...

Page 4: ...o the unit Allow a minimum 15 clear ance to the side of the unit to allow for filter removal and replacement Low Voltage Wiring Unit location should be in an area where field wiring the remote controls low voltage to the unit will be possible Back Draft Damper It is recommended that a backdraft damper be used in the supply duct of the DV090 especially when con necting to the supply ducting system ...

Page 5: ...he remote controls of the DV090 are powered by a low voltage circuit 24VAC and must NEVER contact or be connected to a high voltage circuit The control wires leaving the DV090 and the control are numbered and color coded to prevent confusion Some of the control wires leaving the DV090 may not be used with certain control and should be left unconnected with wire nuts taped onto the stripped ends fo...

Page 6: ...collars to the DV090 Step 1 Attach 6 diameter fresh air ventilation damper if desired Safety Float Switch the DV090 and the dehumidifier will shut off If the blue wire is in series with the Safety Float Switch the compressor will turn off but the DV090 will continue to ventilate or circulate air as normal Contact your local electrician to install the safety float switch directly to the dehumidifie...

Page 7: ... for 90 flow option 180 Flow Attach the second 10 duct collar as you did the first Use six 8 screws provided Ducting for Dehumidification For the ideal installation draw air from the central part of the home and return it to the isolated areas of the home like the bedrooms den utility room or family room Be sure to utilize as many of these remote rooms as possible and not just one location The duc...

Page 8: ...performance positively or negatively depending upon the inside and outside air conditions The outside air duct should be connected to the 6 round collar on the front of the DV090 The amount of outside air can be restricted by the blade damper in the 6 collar Fresh Air Supply Air I CAUTION DO NOT draw air directly from the kitchen laundry or isolated basement You may draw air from a basement that i...

Page 9: ...If you are unsure of your ventilation air requirements or have need for higher air flows consult Technical Support by calling 1 855 239 2665 Figure 5 Attic Installation Installation in a Basement or Crawlspace with an Existing Forced Air HVAC System Crawlspace Installation Install a separate return to the DV090 in a central area of the home Optional Duct the supply from the DV090 to a 10 x 10 x 10...

Page 10: ...ventilation See Figure 6 Figure 6 Installation with no forced air HVAC system Ducting for High Efficiency Filtration The filter included with the DV090 is a very efficient MERV 11 media filter This filter should be checked every three months and changed every 6 12 months Quiet Installation Consider compression vibration and airflow noise during installation Use of flex duct and or vibration isolat...

Page 11: ...not used do not connect the white wire to the DVP 4034748 control or damage to the transformer may result I CAUTION DO NOT allow the yellow lead from the unit to contact the red lead or the white lead from the unit or damage to the transformers will result A 40VA transformer is wired between the red white lead and the yellow leads of the DV090 This low voltage power source powers the relay coils w...

Page 12: ...ty Range Accuracy 10 95 RH 5 Humidity Range Set Point 35 70 RH Auxiliary Relay Capacity 5 Amps 24VAC Temp Range Accuracy 30 90 F 1 32 C 2 Size 4 95 L x 1 06 W x 4 19 H 12 6 cm L x 2 7 cm W x 10 6 cm H Major Operations Digital control of Relative Humidity Digital Set Point Fan Filter Operation Programmable Ventilation Timer Large easy to read backlit LCD display Easy interaction with air handler fa...

Page 13: ...ic for DV090 Wiring Schematic I WARNING Servicing the DV090 with its high pressure refrigerant system and high voltage circuitry presents a health hazard which could result in death serious bodily injury and or property damage Call your HVAC contractor for servicing or repair of this equipment To replace the filter remove the filter door from the side of the DV090 dehumidifier by gently pulling it...

Page 14: ...ator and compresses it to a high pressure and temperature to repeat the process Troubleshooting Neither fan nor compressor running Dehumidification is being called for No fan call 1 Unit unplugged or no power to outlet 2 Humidity control set too high 3 Loose connection in internal or control wiring 4 Defective Compressor relay 5 Defective control transformer Compressor is not running Dehumidificat...

Page 15: ...1 855 239 2665 Refrigerant Charging If the refrigerant charge is lost due to service or a leak a new charge must be accurately weighed in If any of the old charge is left in the system it must be recovered before weighing in the new charge Refer to the unit nameplate for the correct charge weight and refrigerant type Compressor Capacitor Replacement This compressor is equipped with a two terminal ...

Page 16: ...la tion at the correct times Motorized Ventilation Damper The motorized ventilation damper is controlled by a field supplied ventilation timer such as the Clean Comfort DVP 4034748 control The damper will open when the ventilation timer is activated to allow fresh air into the home through the 6 diameter fresh air inlet supply duct The motorized ventilation damper will remain closed when the venti...

Page 17: ...allasufficientlylongdrainhosetoconnect thedrainadaptorofthedehumidifiertothecondensate pumpreservoirusingfield suppliedfittings Step 6 Attachadrainhosetothecondensatepump androuteittoafloordrain Step 7 Use a level to ensure the dehumidifier is level before powering up the dehumidifier and the condensate pump Step 8 Plug in the condensate pump and the assembly is completed Annual inspection of a pr...

Page 18: ...nty A defect under the terms of this limited warranty shall not include problems resulting from Customer s or Customer s employees agents invitees or a third party s misuse improper installation improper design of any system in which the Product is included abuse lack of normal care failure to follow written instructions tampering improper repair or freezing corrosion acts of nature or other cause...

Page 19: ...IO DV090 WWW CLEANCOMFORT COM 19 Notes ...

Page 20: ...W CLEANCOMFORT COM IO DV090 2 14 Our continuing commitment to quality products may mean a change in specifications without notice 2014 DAIKIN NORTH AMERICA LLC Houston Texas USA Email info cleancomfort com 1 855 239 2665 ...

Reviews: