background image

OPERATION

IO-DV090

IO-DV090

WWW.CLEANCOMFORT.COM

16

Humidity Control

The humidity control is an adjustable switch that closes 

when the relative humidity of the air in which it is located 

rises to the screen set point. The DV090 dehumidifier is 

equipped with an automatic defrost mechanism. If the 

dehumidifier operates in conditions that develop frost  

on the evaporator, it will sense the frost build-up and  

automatically defrost the evaporator. The dehumidifier 

may not appear to be operating correctly during the 

defrost sequence, but once the defrost sequence is 

completed, the unit will resume dehumidifying.

Programmable Ventilation Timer –  

DVP-4034748 / DVP-4034753

The ventilation timer controls the impeller fan and the 

motorized fresh air damper. When the ventilation timer 

is activated, the dehumidifier will circulate the indoor 

air, and bring in fresh air from outside. The ventilation 

timer should be set for the required ventilation of the 

residence. The home should be ventilated with fresh air 

as suggested by applicable codes and standards.If the 

dehumidifier fails to ventilate as expected, check that the 

time on the timer is correct. Also check the programs on 

the timer to be sure that the timer is calling for ventila-

tion at the correct times

Motorized Ventilation Damper

The motorized ventilation damper is controlled by a field- 

supplied ventilation timer, such as the Clean Comfort  

DVP-4034748 control. The damper will open when the  

ventilation timer is activated to allow fresh air into the  

home through the 6" diameter fresh air inlet supply duct.  

The motorized ventilation damper will remain closed when  

the ventilation timer is not activated to prevent over-ventilating 

the home when the unit is dehumidifying or recirculating  

the indoor air. The motorized ventilation damper operates  

on 24VAC from the control circuit. 

I

 

CAUTION!

 

DO NOT connect high voltage to the damper motor or 

 

damage to the motor may result.

 

I

 

CAUTION!

 

DO NOT force the blade of the damper by hand or 

 

damage to the damper motor may result. The damper 

 

opens in one direction only. The damper rotates very 

 

slowly; allow sufficient time for the damper to cycle. 

 

The damper opens in one direction only. It rotates very 

slowly; be sure to allow sufficient time for the damper to 

cycle. The damper will take approximately one minute to 

cycle from closed to open or from open to closed.

 

If the motorized ventilation damper fails to operate:

1.  Check that the wiring is correct and that voltage is 

present at the damper motor.

2.  Check for any obstruction inside the damper. If the 

motorized ventilation damper fails to operate after 

performing these checks, it must be replaced.

Summary of Contents for DV090

Page 1: ...l the incoming air stream below its dew point This cooled and drier air is used to pre cool the incoming air stream resulting in increased overall efficiency After the pre cooling stage the processed air is reheated by passing through the condenser coil Fresh Air Ventilation Optional Fresh outdoor air may be ducted to the dehumidifier This provides fresh air to dilute indoor pollutants and repleni...

Page 2: ... Daikin North America LLC All rights reserved INTRODUCTION 1 SAFETY PRECAUTIONS 3 INTENDED APPLICATION 3 REGISTRATIONS 3 OPTIONAL PARTS LIST 3 SPECIFICATIONS 3 INSTALLATION 3 Installation Considerations 4 Power Accessibility 4 Space 4 Low Voltage Wiring 4 Back Draft Damper 4 Support Structure and Suspension 4 Electrical Requirements 4 Condensate Water Removal 5 Lifting Condensate 5 Condensate Pump...

Page 3: ...apacity 90 Pints Day 43 L Day Efficiency 5 3 pints kWhr 2 5 L kWhr Duct Connections 6 Round Inlet 10 Round Inlet 10 Round Outlet Air Filter Efficiency MERV 11 Standard 65 Efficient ASHRAE Dust Spot Test Size 14 X 14 x1 Power Cord 8 ft 2 4 m Drain Connection 3 4 Threaded FNPT Refrigerant Type R410a Refer to manufacturers label for more information Dimensions Unit Shipping Width 15 39 cm 18 47 cm He...

Page 4: ...o the unit Allow a minimum 15 clear ance to the side of the unit to allow for filter removal and replacement Low Voltage Wiring Unit location should be in an area where field wiring the remote controls low voltage to the unit will be possible Back Draft Damper It is recommended that a backdraft damper be used in the supply duct of the DV090 especially when con necting to the supply ducting system ...

Page 5: ...he remote controls of the DV090 are powered by a low voltage circuit 24VAC and must NEVER contact or be connected to a high voltage circuit The control wires leaving the DV090 and the control are numbered and color coded to prevent confusion Some of the control wires leaving the DV090 may not be used with certain control and should be left unconnected with wire nuts taped onto the stripped ends fo...

Page 6: ...collars to the DV090 Step 1 Attach 6 diameter fresh air ventilation damper if desired Safety Float Switch the DV090 and the dehumidifier will shut off If the blue wire is in series with the Safety Float Switch the compressor will turn off but the DV090 will continue to ventilate or circulate air as normal Contact your local electrician to install the safety float switch directly to the dehumidifie...

Page 7: ... for 90 flow option 180 Flow Attach the second 10 duct collar as you did the first Use six 8 screws provided Ducting for Dehumidification For the ideal installation draw air from the central part of the home and return it to the isolated areas of the home like the bedrooms den utility room or family room Be sure to utilize as many of these remote rooms as possible and not just one location The duc...

Page 8: ...performance positively or negatively depending upon the inside and outside air conditions The outside air duct should be connected to the 6 round collar on the front of the DV090 The amount of outside air can be restricted by the blade damper in the 6 collar Fresh Air Supply Air I CAUTION DO NOT draw air directly from the kitchen laundry or isolated basement You may draw air from a basement that i...

Page 9: ...If you are unsure of your ventilation air requirements or have need for higher air flows consult Technical Support by calling 1 855 239 2665 Figure 5 Attic Installation Installation in a Basement or Crawlspace with an Existing Forced Air HVAC System Crawlspace Installation Install a separate return to the DV090 in a central area of the home Optional Duct the supply from the DV090 to a 10 x 10 x 10...

Page 10: ...ventilation See Figure 6 Figure 6 Installation with no forced air HVAC system Ducting for High Efficiency Filtration The filter included with the DV090 is a very efficient MERV 11 media filter This filter should be checked every three months and changed every 6 12 months Quiet Installation Consider compression vibration and airflow noise during installation Use of flex duct and or vibration isolat...

Page 11: ...not used do not connect the white wire to the DVP 4034748 control or damage to the transformer may result I CAUTION DO NOT allow the yellow lead from the unit to contact the red lead or the white lead from the unit or damage to the transformers will result A 40VA transformer is wired between the red white lead and the yellow leads of the DV090 This low voltage power source powers the relay coils w...

Page 12: ...ty Range Accuracy 10 95 RH 5 Humidity Range Set Point 35 70 RH Auxiliary Relay Capacity 5 Amps 24VAC Temp Range Accuracy 30 90 F 1 32 C 2 Size 4 95 L x 1 06 W x 4 19 H 12 6 cm L x 2 7 cm W x 10 6 cm H Major Operations Digital control of Relative Humidity Digital Set Point Fan Filter Operation Programmable Ventilation Timer Large easy to read backlit LCD display Easy interaction with air handler fa...

Page 13: ...ic for DV090 Wiring Schematic I WARNING Servicing the DV090 with its high pressure refrigerant system and high voltage circuitry presents a health hazard which could result in death serious bodily injury and or property damage Call your HVAC contractor for servicing or repair of this equipment To replace the filter remove the filter door from the side of the DV090 dehumidifier by gently pulling it...

Page 14: ...ator and compresses it to a high pressure and temperature to repeat the process Troubleshooting Neither fan nor compressor running Dehumidification is being called for No fan call 1 Unit unplugged or no power to outlet 2 Humidity control set too high 3 Loose connection in internal or control wiring 4 Defective Compressor relay 5 Defective control transformer Compressor is not running Dehumidificat...

Page 15: ...1 855 239 2665 Refrigerant Charging If the refrigerant charge is lost due to service or a leak a new charge must be accurately weighed in If any of the old charge is left in the system it must be recovered before weighing in the new charge Refer to the unit nameplate for the correct charge weight and refrigerant type Compressor Capacitor Replacement This compressor is equipped with a two terminal ...

Page 16: ...la tion at the correct times Motorized Ventilation Damper The motorized ventilation damper is controlled by a field supplied ventilation timer such as the Clean Comfort DVP 4034748 control The damper will open when the ventilation timer is activated to allow fresh air into the home through the 6 diameter fresh air inlet supply duct The motorized ventilation damper will remain closed when the venti...

Page 17: ...allasufficientlylongdrainhosetoconnect thedrainadaptorofthedehumidifiertothecondensate pumpreservoirusingfield suppliedfittings Step 6 Attachadrainhosetothecondensatepump androuteittoafloordrain Step 7 Use a level to ensure the dehumidifier is level before powering up the dehumidifier and the condensate pump Step 8 Plug in the condensate pump and the assembly is completed Annual inspection of a pr...

Page 18: ...nty A defect under the terms of this limited warranty shall not include problems resulting from Customer s or Customer s employees agents invitees or a third party s misuse improper installation improper design of any system in which the Product is included abuse lack of normal care failure to follow written instructions tampering improper repair or freezing corrosion acts of nature or other cause...

Page 19: ...IO DV090 WWW CLEANCOMFORT COM 19 Notes ...

Page 20: ...W CLEANCOMFORT COM IO DV090 2 14 Our continuing commitment to quality products may mean a change in specifications without notice 2014 DAIKIN NORTH AMERICA LLC Houston Texas USA Email info cleancomfort com 1 855 239 2665 ...

Reviews: