13
light flash jumper
This jumper is used to determine the light flash output. In the (+) position, the on-board relay is enabled and
the unit will output (+)12V on the WHITE wire, H1/2. In the (-) position, the on-board relay is disabled. The
WHITE wire, H1/2, will supply a 200 mA (-) output suitable for driving factory parking light relays.
N
NO
OTTEE:: For parking light circuits that draw 10 amps or more, the jumper must be switched to a (-) light
flash output. A standard automotive SPDT relay must be used on the H1/2 light flash output harness wire.
bypassing sensor inputs
There are times when you need to temporarily bypass all sensor inputs to the unit, such as when remote
starting the vehicle. Anytime an auxiliary channel output is used, all inputs are bypassed for five sec-
onds. During the five second bypass period, ground can be supplied to the H1/6 Blue wire without
triggering the unit. When the five second bypass period ends, if the unit sees ground on the H1/6 Blue
wire, all trigger inputs except the door trigger input will remain bypassed until five seconds after ground
is removed from the BLUE wire. This can be done using the (-) output of a remote engine starting unit
as shown in the following diagram:
module programming routine
The Module Programming Routine dictates how the unit operates. Due to the number of steps, they have
been broken up into two menus. It is possible to access and change any of the feature settings using
the Override switch. However, this process can be greatly simplified by using the Pro Security
Programmer. Any of the settings can be changed and then assigned to a particular remote, up to four,
a feature called individual recognition. Each time that particular remote is used to disarm the system,
the assigned feature settings will be recalled. Individual recognition is only possible when programming
the unit via the Pro Security Programmer.
If the system was previously programmed using the Pro Security Programmer, the learn routine may be
locked. If the siren generates one long chirp when attempting to program the unit, the Module
Programming Routine is locked and must be unlocked using the Pro Security Programmer.
1N4004 DIODE
TO OPTIONAL HOOD/
TRUNK PINS OR SENSORS
CONTROL UNIT
REMOTE
START UNIT
(-) OUTPUT
BLUE WIRE H1/6
ZONE 1 INPUT
IIm
mp
poorrtta
anntt!! DO NOT connect the H1/2 light flash wire to a negative vehicle light flash wire
before changing the programming jumper to the negative polarity position or damage to
vehicle light circuit may occur.