9
H1/12 RED/WHITE
200 mA (-) channel 2 output
When the system receives the code controlling channel 2 for longer than 1.5 seconds, the RED/WHITE
will supply an output as long as the transmission continues. This is often used to operate a trunk/hatch
release or other relay/driven function.
door lock harness (H2), 3-pin connector
___
___
___
IIm
mp
poorrtta
anntt!! The door lock outputs are low current and should not be attached directly to any
high current device; they are only to be used to activate relays
Blue
(-) Unlock, (+) Lock Output
Empty
Unless Using 451M
Green
(-) Lock, (+) Unlock Output
H2/A
H2/B
H2/C
IIM
MPPO
ORRTTA
AN
NTT!! Never use this wire to drive anything but a relay or a low-current input! The
transistorized output can only supply 200 mA of current. Connecting directly to a solenoid,
motor, or other high-current device will cause it to fail.