background image

P.3

Content

1. Important notes
    1.1 Using the instructions
    1.2 Safety instructions
2. Description of appliance

    2.1 Technical specifications 

    2.2 Dimensions 
    2.3 Scope of delivery
3. Installation
    3.1 Typical installations
    3.1.1 Vented (open) installation 
    3.1.2 Pressure-resistant (closed) outlet installations
    3.2 Installation instructions
    3.3 Water connection 
    3.4 Electrical connection
    3.5 Initial start-up
4. Use
    4.1 Rating plate cover
    4.1.1 Removing the cover
    4.1.2 Replacing the cover

    4.2 Adjusting the water flow and temperature

    4.3 Changing the strainer 
    4.4 Purging
    4.5 Cleaning and maintenance
5. Troubleshooting
6. Disposal
    6.1 Disassembly
    6.2 Environment and recycling 
7. Warranty Terms & Conditions

03
03
03
06
06

07
07

08
08
08
09
09

10
11

12
13
13
13
13

14
15
15
15
16

18
18
19
35

1.Important Notes

1.1 Using the instructions

Please read these instructions carefully before installing or using the appliance! Keep the instructions 

handy with the appliance for future use! These instructions are intended for the specialist who is responsible for 

the installation of the appliance, and for the end user.

The latest version of the instructions can be found online at www.germanpool.com. 

1.2 Safety instructions

- Do not use the appliance until it has been correctly installed and 

unless it is in perfect working order.

- Do not remove the front cover under any circumstances before 

switching off the mains electrical supply to the unit.

- Never make technical modifications, either to the appliance itself 

or the electrical leads and water pipes.

- The appliance must be earthed at all times.
- Pay attention to the fact that water temperatures in excess of approx. 

43°C are perceived as hot, especially by children, and may cause a 

feeling of burning. Please note that the fittings and taps may be very 

hot when the appliance has been in use for some time.

- The appliance is only suitable for domestic use and similar 

applications inside closed rooms, and must only be used to heat 

incoming water from the mains supply.

- The appliance must never be exposed to frost.
- The values stated on the rating plate must be observed.
- In case of malfunction, disconnect the fuses immediately. In case 

of leaks, cut off the mains water supply instantly. Repairs must 

only be carried out by the customer service department or an 

authorised professional.

Summary of Contents for German pool GPI-M3

Page 1: ...nty information carefully before use and keep them handy for future reference Online Warranty Registration U S E R M A N U A L GPI M3 Instantaneous Electric Water Heater WH GPI M3 M 18 1 Printed in Ge...

Page 2: ...lation of the appliance and for the end user The latest version of the instructions can be found online at www germanpool com 1 2 Safety instructions Do not use the appliance until it has been correct...

Page 3: ...on the mains side of the connecting box for appliances with a fixed connection The wall bracket must be secured with the supplied screws and dowels The appliance must be secured to the wall bracket Th...

Page 4: ...r rating 2 86 kW Nominal current 13 A Hot water flow rate at t 25 K 2 2 0 L min Switching on at 1 2 L min Minimum required cable size 1 5 mm2 Approx weight filled with water 1 5 kg Product dimensions...

Page 5: ...a 2 4 bar The appliance must not be subjected to pressure exceeding 1 MPa 10 bar For safe operation of this instantaneous water heater a non return valve is not required If nevertheless a non return v...

Page 6: ...3 Water connection 1 Position the instantaneous electric water heater with the water connectors vertically upward or downward for direct connection to the tap 2 Secure the wall bracket to the wall wit...

Page 7: ...ration card or online at www germanpool com 3 Installation As soon as the hot water tap is opened the instantaneous water heater switches on automatically Close the tap and the appliance switches off...

Page 8: ...water emerges free of air bubbles 3 Switch the power supply back on again 4 5 Cleaning and maintenance Plastic surfaces and fittings should only be wiped with a damp cloth Do not use abrasive or chlo...

Page 9: ...close other taps open angle valve further Water remains cold even though the appliance switches on Electric supply incorrect Check the electric supply No voltage Check fuses in the electrical install...

Page 10: ...scrap 6 Disposal 6 1 Disassembly 1 Switch off the power supply to the instantaneous water heater 2 Close the shut off valve in the inlet pipe 3 Disconnect the electrical connection in the appliance ju...

Page 11: ...2 1 5 1 5 kg x x 13 5 18 6 8 7 cm IES VDE IP25 No 812 2013 1 2 15 40 www germanpool com 0 6 MPa 0 6 MPa 1 1 1 1 2 2 2 1 2 2 2 3 3 3 1 3 1 1 3 1 2 3 2 3 3 3 4 3 5 4 4 1 4 1 1 4 1 2 4 2 4 3 4 4 4 5 5 6...

Page 12: ...P 22 P 23 2 2 2 186 115 15 4 5 135 155 141 87 25 30 150 G 550 850 133 22 75 186 70 553 135 520 3 3 1 3 1 1 2 3 2 9 kW CSP 3...

Page 13: ...P 24 P 25 3 2 German Pool DIN VDE 0100 EN 806 0 2 0 4MPa 2 4bar 1MPa 10bar 3 3 1 2 3 a b c d e 6 7 4 5 3 3 1 2 G 550 850 133 22 75 186 70 553 135 520 a a d b c e 3 2 9 kW CSP 3...

Page 14: ...P 26 P 27 3 4 1 2 3 4 5 3 3 5 1 2 3 4 5 6 www germanpool com 3 220 V...

Page 15: ...P 28 P 29 4 4 4 1 1 2 3 4 1 1 1 2 3 1 2 AAAA Ger t an Schutzleiter anschlie en Appliance must be earthed BBBB CCCC 3 4 1 2 1 2 4 2 40 30 25 20 10 0 0 0 1 0 2 0 l min K 3 0 4 0 5 0 2 9kW...

Page 16: ...P 30 P 31 4 3 1 2 3 4 5 6 7 4 4 1 2 3 4 5 4 5...

Page 17: ...P 32 P 33 35 5 6 1 1 2 3 4 5 15 6 6 1 10 2 15 3...

Page 18: ...ill at its discretion repair or replace any defective part 5 This warranty will be void if there is any transfer of ownership from the original purchaser 1 2 3 4 5 Serial No Purchased From Invoice No...

Page 19: ...Edificio Industrial Pou Fung 145 Rua de Francisco Xavier Pereira Macau Tel 853 2875 2699 Fax 853 2875 2661 Macau All rights reserved Copying reproducing or using the contents of this manual is not all...

Reviews: