background image

P.6

P.7

2. Description of Appliance 

2.2 Dimensions 

       

Dimensions: mm

2.3 Scope of delivery

186

115

15

4.5

135

155

141

87

25

30

150

Instantaneous water heater 

Operating and installation 

instructions

Wall bracket

2. Description of Appliance 

This instantaneous electric water heater is intended to provide the economical heating of water sufficient for a 

single outlet, i.e. handwash basin, and is installed together with a sanitary water fitting.

When the hot water tap is opened, the instantaneous electric water heater switches itself on automatically 

and heats the water as it passes through the appliance. It is only then that the appliance uses electricity. 

The temperature increase depends on the flow rate.

2.1 Technical specifications

Model

GPI-M3

Energy efficiency class

#

Capacity                                                                 

0.2 l

Nominal pressure             

1 MPa / 10 bar

Minimum resistance of the water at 15°C

1)

 

1100 Ω cm

Supply voltage                                                            

1~ / N / PE 220 V AC

Nominal power rating                                             

2.86 kW

Nominal current                                                         

13 A

Hot water flow rate at ∆t = 25 K 

2)

 

              

2.0 L/min

Switching on at                                                  

1.2 L/min

Minimum required cable size                             

1.5 mm

2

Approx. weight (filled with water)                            

1.5 kg

Product dimensions (Height × Width × Depth)                 13.5 × 18.6 × 8.7 cm

Type

IES® Bare wire heating system

VDE approv. / Protec. class

VDE / IP25

#) The declaration complies with the preliminary requirements of the EU regulation No 812/2013.

1) The specific resistance can be asked for at your water distribution company.

2) Temperature increase from e. g. 15 °C to 40 °C.

• 

Specifications are subject to change without prior notice.

• 

If there is any inconsistency or ambiguity between the Chinese version and the English version, the 

English version shall prevail.

• 

Refer to www.germanpool.com for the most up-to-date version of the User Manual.

• 

Under normal working conditions, incoming pressure should not exceed 0.6 MPa. Otherwise, a sepa-

rate pressure control device is necessary.

• 

When incoming water pressure exceeds 0.6 MPa, German Pool will not provide any repair service until 

a pressure control device is installed.

Fixing screws 

and plugs

Special jet 

regulator

Summary of Contents for German pool GPI-M3

Page 1: ...nty information carefully before use and keep them handy for future reference Online Warranty Registration U S E R M A N U A L GPI M3 Instantaneous Electric Water Heater WH GPI M3 M 18 1 Printed in Ge...

Page 2: ...lation of the appliance and for the end user The latest version of the instructions can be found online at www germanpool com 1 2 Safety instructions Do not use the appliance until it has been correct...

Page 3: ...on the mains side of the connecting box for appliances with a fixed connection The wall bracket must be secured with the supplied screws and dowels The appliance must be secured to the wall bracket Th...

Page 4: ...r rating 2 86 kW Nominal current 13 A Hot water flow rate at t 25 K 2 2 0 L min Switching on at 1 2 L min Minimum required cable size 1 5 mm2 Approx weight filled with water 1 5 kg Product dimensions...

Page 5: ...a 2 4 bar The appliance must not be subjected to pressure exceeding 1 MPa 10 bar For safe operation of this instantaneous water heater a non return valve is not required If nevertheless a non return v...

Page 6: ...3 Water connection 1 Position the instantaneous electric water heater with the water connectors vertically upward or downward for direct connection to the tap 2 Secure the wall bracket to the wall wit...

Page 7: ...ration card or online at www germanpool com 3 Installation As soon as the hot water tap is opened the instantaneous water heater switches on automatically Close the tap and the appliance switches off...

Page 8: ...water emerges free of air bubbles 3 Switch the power supply back on again 4 5 Cleaning and maintenance Plastic surfaces and fittings should only be wiped with a damp cloth Do not use abrasive or chlo...

Page 9: ...close other taps open angle valve further Water remains cold even though the appliance switches on Electric supply incorrect Check the electric supply No voltage Check fuses in the electrical install...

Page 10: ...scrap 6 Disposal 6 1 Disassembly 1 Switch off the power supply to the instantaneous water heater 2 Close the shut off valve in the inlet pipe 3 Disconnect the electrical connection in the appliance ju...

Page 11: ...2 1 5 1 5 kg x x 13 5 18 6 8 7 cm IES VDE IP25 No 812 2013 1 2 15 40 www germanpool com 0 6 MPa 0 6 MPa 1 1 1 1 2 2 2 1 2 2 2 3 3 3 1 3 1 1 3 1 2 3 2 3 3 3 4 3 5 4 4 1 4 1 1 4 1 2 4 2 4 3 4 4 4 5 5 6...

Page 12: ...P 22 P 23 2 2 2 186 115 15 4 5 135 155 141 87 25 30 150 G 550 850 133 22 75 186 70 553 135 520 3 3 1 3 1 1 2 3 2 9 kW CSP 3...

Page 13: ...P 24 P 25 3 2 German Pool DIN VDE 0100 EN 806 0 2 0 4MPa 2 4bar 1MPa 10bar 3 3 1 2 3 a b c d e 6 7 4 5 3 3 1 2 G 550 850 133 22 75 186 70 553 135 520 a a d b c e 3 2 9 kW CSP 3...

Page 14: ...P 26 P 27 3 4 1 2 3 4 5 3 3 5 1 2 3 4 5 6 www germanpool com 3 220 V...

Page 15: ...P 28 P 29 4 4 4 1 1 2 3 4 1 1 1 2 3 1 2 AAAA Ger t an Schutzleiter anschlie en Appliance must be earthed BBBB CCCC 3 4 1 2 1 2 4 2 40 30 25 20 10 0 0 0 1 0 2 0 l min K 3 0 4 0 5 0 2 9kW...

Page 16: ...P 30 P 31 4 3 1 2 3 4 5 6 7 4 4 1 2 3 4 5 4 5...

Page 17: ...P 32 P 33 35 5 6 1 1 2 3 4 5 15 6 6 1 10 2 15 3...

Page 18: ...ill at its discretion repair or replace any defective part 5 This warranty will be void if there is any transfer of ownership from the original purchaser 1 2 3 4 5 Serial No Purchased From Invoice No...

Page 19: ...Edificio Industrial Pou Fung 145 Rua de Francisco Xavier Pereira Macau Tel 853 2875 2699 Fax 853 2875 2661 Macau All rights reserved Copying reproducing or using the contents of this manual is not all...

Reviews: