Notes for CI valves software version 332.2
Starting a manual Regeneration
Press and hold the REGEN button until the motor starts.
Set a delayed regeneration
Press the REGEN button (REGEN TODAY) will flash on screen) press
the REGEN button again to clear.
Advancing through a regeneration
Press the REGEN button to move to the next stage of regeneration.
Doing a soft reset
Press & Hold REGEB & NEXT for 3 seconds. (resets valve in error).
Doing a total reset
Press & Hold REGEB & NEXT for 3 seconds, then press & hold the
UP & DOWN buttons togeter for 3 seconds. (resets valves history).
Changing the service display
Press NEXT to toggle to the next available display.
Note
Options
1
Off
ALT A
ALT B
SYS
SEPS
nHbP
2
Off
dpon0
dPdEL
Hold
3
Auto
OFF
M³
4
NORMAL
On 0
Normal on 0
5
OFF
Time on
L Softening on
6
OFF
Time on
L Softening on
Error
7
8
OFF
Delay
8a
PrE
9
PrE
Feature not used (standard setting)
Set on primary valve is using a standard duplex alternating systen (Duplex only)
Secondary valve if using a standard duplex alternating system (Duplex only)
If being used with a system controller.
Used if a separate source MAV is being fitted (requires 3 way Mav valve)
Used if a No Untreated Water valve is being fitted (no untreated water during regen)
Feature not used (standard setting) If used the following options are available)
If the contact is closed it will initiate an immediate regeneration.
If the contact is closed it will initiate a delayed regeneration.
If the contact is closed a regeneration will be prevented.
Activates after a set time from the start of a regeneration for a set period of time.
Capacity is automatically calculated and a reserve will be estimated.
Regenerations will be controlled from the day override setting (user settings)
Regeneration will occur immediately when the set capacity has expired.
If off or M³ is selected the hardness setting will not display in settings.
Regenerations will occur at the pre set time. (not available on alternating duplex)
Regenerations will occur immediately when capacity reaches zero.
Regeneration will occur at the preset time when volume is below the reserve or if
volume is below the reserve after 10 minutes of no water usage.
Feature not used.
Activates in service after a set number of litres for a set time and deactivates after
a set period of flow stops.
As above but during regeneration.
Feature not used.
L Softening Regen on
Activates in service after a set number of litres for a set time and deactivates after
a set period of flow stops.
As above but during regeneration.
Activates whenever the valve enters an error mode.
Activates after a set time from the start of a regeneration for a set period of time.
Add the KG of salt added to the brine bin each fill, doe's not show for 1.5 & 2" valves.
L Softening Regen on
Standard setting.
The last two cycles can be delayed (Rinse & Fill) this delays untl the on line unit is
depleted to 10%.
A pre sinse can be set to rinse the next cylinder before going into service (1" 2" & 1" TT)
A pre rinse can be set if required of up to 20 min duration.