11
Programming the Valve (TC Only)
Should the programming have been lost in transit the following instructions in
conjunction with the setting sheet will allow you to re set them.
When the power has been connected the valve will display the software number and initialise
itself and then display
TIME
; you can then start to program the valve.
Selections are made using the
UP
and
DOWN
buttons until
the required setting is displayed; after each setting press
SET HOUR
to continue.
Step 1: System Setup.
Press
SET HOUR + UP
button simultaneously for three seconds and release.
Then press
SET HOUR + UP
button simultaneously for three seconds and release.
Select the chosen program P7 to P9 (see setting sheet) two dashes with an arrow pointing
towards Min Fill will display; press
SET HOUR
to continue.
99
with an arrow pointing to Days to Regen will now flash
select 99
and continue
SET HOUR
.
50
with three arrows each side will now flash
select 50
and continue
SET HOUR
this
represents 50Hz frequency..
dp
will now display; standard systems are not fitted with a dp switch and consequently this
setting is ignored.
Step 2: Display Settings.
Press
SET HOUR + UP
button simultaneously for three seconds and release.
The
REGENERTION / BACKWASH
time is now showing; use the
UP
and
DOWN
buttons to
adjust to the hour required (default 2am).
Days between
REGEN / BACKWASH
is now showing; use the
UP
and
DOWN
buttons to
adjust to the days required (default 3).
The valve can be set to regenerate on specific days; information is supplied in the full valve
manual (available on request)
Quick Start.
Set Time of Day.
Press
SET HOUR
and adjust time using the
UP
or
DOWN
buttons.