8
The valve is supplied pre programmed!
(Excluding settings that need to be done on site)
The settings are listed in case there is a need to re program the
unit
.
If you have any concerns or worries following the setting procedure please contact your
supplier who will help you through the set up procedure.
Using the above information to identify your system you can then select the relevant setting
sheet from the following pages.
2.8 Programming the Valve (CI Only)
Should the programming have been lost in transit the following instructions in
conjunction with the setting sheet will allow you to re set them.
When the power has been connected the valve will display the software number and initialise
itself and then display
TIME
; you can then start to program the valve.
Selections are made using the
UP
and
DOWN
buttons until the required setting is displayed;
after each setting press
NEXT
to continue.
Set the Time of Day
(As above)
Step 1: Cycle Sequence.
Press
NEXT
and
DOWN
simultaneously for 3 seconds and release.
The screen will display SOFTENING flashing!
Press
NEXT
and
DOWN
simultaneously for 3 seconds.
The screen should display SET 25, adjust as necessary (see setting sheet page?) Press
NEXT
and set each setting accordingly until the display returns to
TIME
. (See notes if fitting a
Motorised Alternating Valve or No Hard / untreated Water Bypass valve)
Step 2: System Setup.
Press
NEXT
and
DOWN
simultaneously for 3 seconds and release.
The screen will display SOFTENING flashing.
Change this to FILTERING.
The screen should display CYCLE 1, adjust as necessary (see setting sheet page?) Press
NEXT
and set each setting accordingly until the display returns to
TIME
.
Quick Start CI.
Set Time of Day.
Press
SET CLOCK.
Adjust the hours and press
NEXT
to adjust the minutes, press
NEXT
to return to the
normal
TIME
display.
Summary of Contents for Water Specialist CI WS1
Page 19: ...19 Troubleshooting...
Page 20: ...20...
Page 21: ...21...
Page 22: ...22 Manual 018 0...