Clack WS / CI Valves Set up as Filters.
pH, Sand, Turbidex, Aquamandix, Birm, Arsenic.
Please apply the settings in the following sequence.
Selections are made using the UP and DOWN buttons until the required setting is displayed.
After each setting press NEXT to continue.
Vessel Size
1044
1054
1252
1354
1465
1665
1865
2160
2469
3072
3672
Media Vol (1/2 Cuft) Filox
2
3
4
6
8
10
12
16
22
Media Vol (Cuft) Birm
1.5
2
2.5
3
3.5
5
6.5
9
15
20
Media Vol (Cuft) Turbidex
1
2
2.5
4
5
7
8
11
Media Vol (Kg) Sand
32
50
37.5
100
125
150
225
250
400
625
900
Media Vol (Kg) pH
50
62.5
100
125
150
225
250
400
650
925
Media Vol (Kg) Bayoxide
15
30
45
60
75
105
150
225
300
Media Vol (Kg) Carbon
20
25
35
50
63
85
100
150
200
300
Valves
1"
1"
1"
1"
1"
1"
1"
1.25"
1.5"
1.5"
2"
2"
2"
Step 1, Cycle Sequence,
Press NEXT and DOWN simultaneously for 3 seconds and release.
Screen will display SOFTENING flashing.
Press NEXT and DOWN simultaneously for 3 seconds, the screen will display SET 1, Adjust to the turbine setting below.
Turbine Size WS1
1
1
1
1
1
1
1
Turbine Size WS1.25
1.25
Turbine Size WS1.5
1.5
1.5
Turbine Size WS2
2
2
2
Alternating
DP
Set Hardness
SET Cycle 1
SET Cycle 2
SET Cycle 3
SET Cycle 4
SET Cycle 5
Step 2, System Setup.
Press NEXT and DOWN simultaneously for 3 seconds and release.
Screen will display SOFTENING flashing.
Change this to FILTERING.
Cycle 1 Backwash
5
5
5
5
5
5
5
5
5
5
5
Cycle 2 Rinse
3
3
3
3
3
3
3
3
3
3
3
Cycle 3 2nd Backwash
5
5
5
5
5
5
5
5
5
5
5
Cycle 4 2nd Rinse
3
3
3
3
3
3
3
3
3
3
3
Cycle 5 End
Set Regen
Set Time Regen
Set rLY 1 (Relay 1)
Set rLY 2 (Relay 2)
Step 3, Display Settings.
Press NEXT and UP simultaneously for 3 seconds and release.
Regen Day
Regen Day (Arsenic)
Set Time Regen Hrs
Set Time Regen Min
Step 4. Set time of day,
Press SET CLOCK
Set hours using the up and down buttons.
Set minutes using the up and down buttons.
Off
PPM
Backwash
Rinse
END
or (see note 5 for options)
or (see note 6 for options)
2nd Backwash
2nd Rinse
Default 2:
31/05/2017
Software version from 332.2
Off
or (see note 1 for options)
Off
or (see note 2 for options)
Off
or (see note 3 for options)
End
3
14
Default :00
(will not show if Off selected above)
or (see note 4 for options)
Off
Step 3: Display Settings.
Press
NEXT
and
UP
simultaneously for 3 seconds and release.
HARDNESS with –nA- should appear on screen. Adjust as necessary (see setting sheet
page?) Press
NEXT
and set each setting accordingly; please pay particular attention to the
Regen Day and Regen Time settings, the display will return to the time of day after setting the
regen time (minutes) has been set.
The valves are supplied pre programmed. Listed below are the settings in case
there is a need to re program the unit.