35
Settings:
Cleaning
The preparation pan (1) is the first part of the cleaning system that the grain
will come into contact with. Its function is to separate the grain and the chaff.
The grain is heavier and therefore goes to the bottom, the lighter chaff goes to
the top. It is important that this is kept clean, to allow this to happen effectively.
A dirty preparation pan will cause a poor sample and reduce output.
TIP.
Clean the preparation trays daily, this will help keeping a clean sample.
TIP.
When removing the prep trays for cleaning, blow off the top of the gear
box area to remove any chaff and dust.
The fan (2) speed is shown on
the CEBIS screen. The speed
range of the fan is 680rpm –
1600rpm.
With the jet stream on the
LEXION 700 machines there are
no other adjustments needed
apart from the speed.
TIP.
Only make adjustments of 50rpm at a time.