background image

Cla-Val Product

Identification

Proper Identification

For ordering repair kits, replacement parts, or for
inquiries concerning valve operation it is important to
properly identify Cla-Val products already in service.
Include all nameplate data with your inquiry. Pertinent
product data includes valve function, size, material,
pressure rating, end details, type of pilot controls
used and control adjustment ranges.

Identification Plates

For product identification, cast in body markings are
supplemented by identification plates as illustrated on
this page. The plates, depending on type and size of
product, are mounted in the most practical position. 

It

is extremely important that these identification
plates are not painted over, removed, or in any
other way rendered illegible.

C

®

C

®

This brass plate appears on valves sized 2

1

/

2

" and larger

and is located on the top of the inlet flange.

These two brass plates appear on 

3

/

8

", 

1

/

2

", and 

3

/

4

" size

valves and are located on the valve cover.

These two brass plates appear on 1" through 3" size

screwed valves or 1" through 2" flanged valves . It is

located on only one side of the valve body.

This brass plate appears on altitude valves only and is

found on top of the outlet flange.

This brass plate is used to identify pilot control valves.

The adjustment range is stamped into the plate.

This tag is affixed to the cover of the pilot control valve.

The adjustment range appears in the spring range

section.

This aluminum plate is included in pilot system

modification kits and is to be wired to the new pilot

control system after installation.

This brass plate is on our backflow prevention

assemblies.  It is located on the side of the number two

check (2" through 10"). The serial number of the

assembly is also stamped on the top of the inlet flange of

the number one check.

How to Order

Distributed By: M&M Control Service, Inc.

                http://www.mmcontrol.com/claval-index.php

800-876-0036     847-356-0566

Summary of Contents for 100-01

Page 1: ...01 Distributed By M M Control Service INC Phone 800 876 0036 Fax 847 356 0747 Email Sales mmcontrol com Distributed By M M Control Service Inc http www mmcontrol com claval index php 800 876 0036 847...

Page 2: ...sed slowly open upstream block valve If isolation valves B are installed in the pilot system open these valves see schematic 3 Carefully loosen the plug at top of cover assembly If an indicator X101 i...

Page 3: ...Strainer B CK2 Valve Isolation Valve C CV Flow Control Closing D Check Valves with Isolation Valve S CV Flow Control Opening Y X43 Y Strainer 3 2 D1 Y B1 1 A C B1 S B1 B2 4 OUTLET INLET D2 D3 X58C CDH...

Page 4: ...Distributed By M M Control Service Inc http www mmcontrol com claval index php 800 876 0036 847 356 0566...

Page 5: ...Distributed By M M Control Service Inc http www mmcontrol com claval index php 800 876 0036 847 356 0566...

Page 6: ...Distributed By M M Control Service Inc http www mmcontrol com claval index php 800 876 0036 847 356 0566...

Page 7: ...tions are acceptable Due to size and weight of the cover and internal components of 8 inch and l arger valves installation with the cover UP is advisable This makes internal parts readily accessible f...

Page 8: ...ng out probable causes and remedies the following three checks can be used to diagnose the nature of the problem before maintenance is started They must be done in the order shown Open Cocks Check ups...

Page 9: ...d The stem should also be checked for scale build up See Maintenance section for procedure 11 For valves 6 and smaller the Hytrol Valve s freedom of move ment check can also be done after all pressure...

Page 10: ...he nut and give it a sharp rap rather than a steady pull Usually several blows are sufficient to loosen the nut for further removal On the smaller valves the entire diaphragm assembly can be held by t...

Page 11: ...mechanically restricting the stroke of the valve The cover must be removed the obstruc tion located and removed See Maintenance Section for procedure Inspection of Parts After the valve has been disa...

Page 12: ...ex Nut 8 and larger 4 Stud 8 and larger 5 Cover Bearing 6 Cover 7 Stem Nut 8 Diaphragm Washer 9 Diaphragm 10 Spacer Washers 11 Disc Guide 12 Disc Retainer 13 Disc 14 Stem 15 Seat 16 Body 17 Spring 22...

Page 13: ...a long life of dependable trouble free operation It s smooth flow passages and fully guided disc and diaphragm assembly assure optimum control when used in piping systems requiring remote control pres...

Page 14: ...e Viton Rubber Parts suffix KB Optional diaphragm disc and o ring fabricated with Viton synthetic rubber Viton is well suited for use with mineral acids salt solutions chlorinated hydrocarbons and pet...

Page 15: ...U S gpm or l s V Fluid Velocity feet per second or meters per second P Pressure Drop in psi or bar CV Factor Formulas for computing C Factor Flow Q and Pressure Drop V P CV Q P CV Q P CV Q P 2 V Funct...

Page 16: ...arger valves installation with cover UP is advisable We recommend isolation valves be installed on inlet and outlet for maintenance Adequate space above and around the valve for service personnel shou...

Page 17: ...Distributed By M M Control Service Inc http www mmcontrol com claval index php 800 876 0036 847 356 0566...

Page 18: ...Distributed By M M Control Service Inc http www mmcontrol com claval index php 800 876 0036 847 356 0566...

Page 19: ...Distributed By M M Control Service Inc http www mmcontrol com claval index php 800 876 0036 847 356 0566...

Page 20: ...e Screw 16 Cap Adj Screw PLS 12576 01D 6 MAX Adjusting screw turn clockwise to increase setting 3 8 NPT Inlet 1 3 4 max 3 16 9 2 10 13 1 8 NPT LOW PRESSURE CONNECTION 7 4 3 11 5 1 6 8 3 8 NPT OUTLET A...

Page 21: ...Distributed By M M Control Service Inc http www mmcontrol com claval index php 800 876 0036 847 356 0566...

Page 22: ...evidence of cross threading Check inner and outer screens for clogging embedded foreign particles breaks cracks corrosion fatigue and other signs of damage CLEANING After inspection cleaning of the X...

Page 23: ...Distributed By M M Control Service Inc http www mmcontrol com claval index php 800 876 0036 847 356 0566...

Page 24: ...Check spring for visible distortion cracks and breaks Inspect all parts for damage corrosion and cleanliness CLEANING After disassembly and inspection cleaning of the parts can begin Water service usu...

Page 25: ...r Stamped on Side Description CV Flow Control Part Description Material ITEM DESCRIPTION QUAN 1 Cap SS only 1 2 Nut Jam 1 3 Seat 1 4 Gasket 1 5 Disc 1 6 Spring 1 7 Ring Retaining 1 8 Stem 1 9 O Ring 1...

Page 26: ...Distributed By M M Control Service Inc http www mmcontrol com claval index php 800 876 0036 847 356 0566...

Page 27: ...screen stock number 68373A All other parts available only in replacement assembly Standard 60 mesh pilot system strainer for fluid service PL X43 R 6 00 PARTS LIST Distributed By M M Control Service I...

Page 28: ...of the inlet flange These two brass plates appear on 3 8 1 2 and 3 4 size valves and are located on the valve cover These two brass plates appear on 1 through 3 size screwed valves or 1 through 2 flan...

Page 29: ...any of the foregoing or assume any additional liability or responsibility in connection with the product The liability of Cla Val is limited to material replacements F O B Newport Beach California TE...

Page 30: ...01D 9817902B N A 9817903K 9817905E 9817905E 3 8 1 2 3 4 1 1 1 4 1 1 2 2 2 1 2 3 4 6 8 9169806J 9169807G 9169808E 9169809C 9169810A 9169817F 9169818D 9169819B 9169820K N A N A N A N A N A N A N A 91698...

Page 31: ...Cl CFC2 C1 CSM 11 A2 2 CSM 11 A2 2 33A 1 33A 2 Pilot Assembly Only Complete Float Control less Ball Rod Disc Distributor Seals Mechanical Parts Assy Pilot Assembly Only Complete Internal Assembly Seal...