Software Options 

In addition to the standard software provided with the PDS-750, CTI also offers additional 
software versions as standard options which can be installed in your system at the time of order 
without additional cost. Available standard options include: 
 

  Version 200a:  This is the standard current version which most PDS-750s are provided with.  

Features are the normal features documented in this manual. 

 

  Version 1.04:  This is an expanded patch version which allows separate control of multiple 

CB fixtures per connection port.  In this version, The Config BCD switch is used to select the 
number of DMX values sent to each port when the unit is placed in CB mode (DMX 
managed mode).  Settings: 

Config BCD set to 0 = 3 DMX values per port (standard operation) 
Config BCD set to 6 = 6 DMX values per port allows 2 CB fixtures to be connected 
and run independently.  One unit must be addressed as CK Light #1, the other 
addressed as CK Light # 2.  

Notes  
1.  For 2-fixture configurations, a Color Kinetics Zapi must be used to pre-address the 

second light, as the CTI min-zapi™ will only address units as CK Light # 1. 

2.  Stand Alone features are not available with Ver. 1.04 software 

 

  Version 1.04a:  This is a "low noise" version that is otherwise identical in operation to 1.04.  

With version 1.04a, the PDS-750 only outputs level 

changes

 to the fixture ports.  Since the 

CB fixtures hold the last the valid level data level sent until they receive a change, the 
operation of the units is 

effectively

 the same as if the DMX data is constantly resent.  Since 

this version only sends changes, the total amount of activity on the data Ports is much 
lower, particularly with channels that are left off, as there is 

no data

 sent, 

not even 0s

.   

 
This software was developed to address the issues resulting from installations with cable 
runs that exceed the maximum limit recommended by Color Kinetics. 

 

Notes 
1.  Since the data is only output when changes occur, a light that is connected after a 

level change will not respond to that change. 

2.  As with version 1.04, Stand Alone features are not available with Ver. 1.04a 

software. 

 
Like all of City Theatrical's microprocessor based products, CTI can also develop custom 
software; contact us any time to discuss your unique requirements 

Summary of Contents for Color Kinetics PDS-750-TR

Page 1: ...PDS 750 TR Touring Power Supply Operator s Manual Rev 1 2 2004 City Theatrical Inc Patent Pending ...

Page 2: ...el Features 5 Mains Power Requirements 5 Connecting Color Kinetics fixtures to the PDS 750 TR 5 Operating Modes CB Pass Thru or Stand Alone 6 CB Mode 6 Pass Thru Mode 6 Stand Alone Effects Mode 7 Using the Mini Zapi 10 Installing the PDS 750 TR 10 Software Options 11 Specifications 12 FIGURES Figure 1 PDS 750 TR Front Panel 4 Figure 2 PDS 750 TR Back Panel 5 Figure 3 PDS 750 TR with C Clamps 10 ...

Page 3: ...door use only Keep the unit dry Do not operate the unit if it gets wet Do not operate in excessive heat direct sunlight Be sure installation provides adequate ventilation Both the front and the back side of the unit must be clear of obstruction and allow free airflow There are no user serviceable parts inside Refer to qualified service personnel Compliance Certifications ETL Listed Conforms to UL ...

Page 4: ...hru Mode Alternating Red Green Stand Alone Mode 2 Reset Switch Press to reset the PDS 750 TR s system microprocessor 3 DMX Address Switches Left to right 100 s 10 s 1 s Set address to 000 for Pass Thru mode Set address to any valid address 001 4761 for CB mode 4 Configuration Switch Selects Stand Alone Routines Also may be used for special functions 5 Channel Overload Indicator Lights if internal ...

Page 5: ...male Panel Mount connector a re generated optically isolated DMX output the Unit switches to passive hard wired pass thru if power is lost 10 Fixture Output 1 4P XLR Female for connection of Color Kinetics fixtures 11 Fan do not obstruct 12 Fuse 10A 3AG Mains Power Requirements The PDS 750 TR is is compatible with 100 240 VAC 50 60 Hz Mains Power The unit is provided with a panel mount IEC Input c...

Page 6: ...er of the output that fixture is connected to With the DMX Address set to 001 Fixture 1 DMX 1 2 3 Fixture 2 DMX 4 5 6 etc To put the unit into CB Mode simply set the DMX Address switches to a desired address other than 000 The unit can be set to any valid DMX address however please note that any starting address over 476 will disable some outputs Configuration system setup for CB DMX managed mode ...

Page 7: ... the DMX Address switches and the Config switch Configuration Switch Settings for different Stand Alone Effects 0 No Stand Alone function The System will operate normally in Pass Thru or CB Modes depending on the DMX Address switch settings 1 Fixed Color The DMX address BCDs are used to adjust the red green and blue components DMX 100s controls the red 0 is off and 9 is full DMX 10s controls green...

Page 8: ...enta Red 4 Cross Fade The Cross Fade effect changes from one preset color to another than back again The DMX 100s switch sets the starting color and the DMX 10s switch sets the ending color The user specified speed is controlled by the DMX 1s switch The following speeds are provided 0 5 sec 1 10 sec 2 30 sec 3 1 min 4 2 min 5 15 min 6 30 min 7 1 hr 5 The random color effect produces random colors ...

Page 9: ...3 Yellow 4 Blue 5 Magenta 6 Cyan 7 White 8 9 Black The strobe rate is controlled by the DMX 1s digit The following rates are provided 0 20 sec 1 13 sec 2 10 sec 3 7 5 sec 4 5 sec 5 4 sec 6 3 sec 7 2 sec 7 Variable color strobe steps from color to color Red Green Yellow Blue Magenta Cyan White in a user definable time period at a strobe rate that is also user definable The same strobe rate that is ...

Page 10: ... stops Power the system down 7 Power the system back up to test the units Installing the PDS 750 TR The PDS 750 TR can be mounted to a pipe or truss using standard theatrical C clamps The Unit is provided with holes on each side of the case cover for attaching the C clamps and with a hole in the left edge of the case cover for a safety cable When mounting the PDS 750 TR in this way all necessary c...

Page 11: ...ddress the second light as the CTI min zapi will only address units as CK Light 1 2 Stand Alone features are not available with Ver 1 04 software Version 1 04a This is a low noise version that is otherwise identical in operation to 1 04 With version 1 04a the PDS 750 only outputs level changes to the fixture ports Since the CB fixtures hold the last the valid level data level sent until they recei...

Page 12: ...igurable fade and chase routines for stand alone operation In Stand Alone Mode selected routine is output to DMX Pass Thru for synchronized Stand Alone operation of many CB Supply systems DMX 512 Interface DMX Input via 5P XLR Male Isolated and repeated DMX Pass Thru via 5P XLR Female DMX Address interface utilizing 3 Rotary BCD Switches for DMX Address configuration CK Output Configuration 12 out...

Reviews: