background image

 

 

19 

1.3 min 

20 

1.5 min 

21 

1.6 min 

22 

2 min 

23 

2.3 min 

24 

2.6 min 

25 

3 min 

26 

3.5 min 

27 

4 min 

28 

4.5 min 

29 

5 min 

30 

5.5 min 

31 

6 min 

32 

6.5 min 

33 

7 min 

34 

8 min 

35 

9 min 

36 

10 min 

37 

12 min 

38 

15 min 

39 

20 min 

40 

25 min 

41 

30 min 

42 

40 min 

43 

50 min 

44 

1 hr 

45 

1.5 hr 

46 

2 hr 

 

Color Wash (reverse).Same as above but in counter clockwise rotation (White, 
Yellow, Green, Cyan, Blue, Magenta, & Red). 
 

Cross-Fade. The Cross-Fade effect changes from one preset color to another than 
back again. The DMX 100s switch sets the starting color and the DMX 10s switch 
sets the ending color. The user specified speed is controlled by the DMX 1s switch. 
The following speeds are provided. 

 

5 sec 

10 sec 

30 sec 

1 min 

2 min 

15 min 

30 min 

1 hr 

 

The random color effect produces random colors at user definable speeds. The 
randomly generated color steps from one to the next without and fading. Speed is 
controlled by the DMX 10s and 1s digits. The following speeds are provided: 

 

Summary of Contents for Color Kinetics PDS-750-TR

Page 1: ...PDS 750 TR Touring Power Supply Operator s Manual Rev 1 2 2004 City Theatrical Inc Patent Pending ...

Page 2: ...el Features 5 Mains Power Requirements 5 Connecting Color Kinetics fixtures to the PDS 750 TR 5 Operating Modes CB Pass Thru or Stand Alone 6 CB Mode 6 Pass Thru Mode 6 Stand Alone Effects Mode 7 Using the Mini Zapi 10 Installing the PDS 750 TR 10 Software Options 11 Specifications 12 FIGURES Figure 1 PDS 750 TR Front Panel 4 Figure 2 PDS 750 TR Back Panel 5 Figure 3 PDS 750 TR with C Clamps 10 ...

Page 3: ...door use only Keep the unit dry Do not operate the unit if it gets wet Do not operate in excessive heat direct sunlight Be sure installation provides adequate ventilation Both the front and the back side of the unit must be clear of obstruction and allow free airflow There are no user serviceable parts inside Refer to qualified service personnel Compliance Certifications ETL Listed Conforms to UL ...

Page 4: ...hru Mode Alternating Red Green Stand Alone Mode 2 Reset Switch Press to reset the PDS 750 TR s system microprocessor 3 DMX Address Switches Left to right 100 s 10 s 1 s Set address to 000 for Pass Thru mode Set address to any valid address 001 4761 for CB mode 4 Configuration Switch Selects Stand Alone Routines Also may be used for special functions 5 Channel Overload Indicator Lights if internal ...

Page 5: ...male Panel Mount connector a re generated optically isolated DMX output the Unit switches to passive hard wired pass thru if power is lost 10 Fixture Output 1 4P XLR Female for connection of Color Kinetics fixtures 11 Fan do not obstruct 12 Fuse 10A 3AG Mains Power Requirements The PDS 750 TR is is compatible with 100 240 VAC 50 60 Hz Mains Power The unit is provided with a panel mount IEC Input c...

Page 6: ...er of the output that fixture is connected to With the DMX Address set to 001 Fixture 1 DMX 1 2 3 Fixture 2 DMX 4 5 6 etc To put the unit into CB Mode simply set the DMX Address switches to a desired address other than 000 The unit can be set to any valid DMX address however please note that any starting address over 476 will disable some outputs Configuration system setup for CB DMX managed mode ...

Page 7: ... the DMX Address switches and the Config switch Configuration Switch Settings for different Stand Alone Effects 0 No Stand Alone function The System will operate normally in Pass Thru or CB Modes depending on the DMX Address switch settings 1 Fixed Color The DMX address BCDs are used to adjust the red green and blue components DMX 100s controls the red 0 is off and 9 is full DMX 10s controls green...

Page 8: ...enta Red 4 Cross Fade The Cross Fade effect changes from one preset color to another than back again The DMX 100s switch sets the starting color and the DMX 10s switch sets the ending color The user specified speed is controlled by the DMX 1s switch The following speeds are provided 0 5 sec 1 10 sec 2 30 sec 3 1 min 4 2 min 5 15 min 6 30 min 7 1 hr 5 The random color effect produces random colors ...

Page 9: ...3 Yellow 4 Blue 5 Magenta 6 Cyan 7 White 8 9 Black The strobe rate is controlled by the DMX 1s digit The following rates are provided 0 20 sec 1 13 sec 2 10 sec 3 7 5 sec 4 5 sec 5 4 sec 6 3 sec 7 2 sec 7 Variable color strobe steps from color to color Red Green Yellow Blue Magenta Cyan White in a user definable time period at a strobe rate that is also user definable The same strobe rate that is ...

Page 10: ... stops Power the system down 7 Power the system back up to test the units Installing the PDS 750 TR The PDS 750 TR can be mounted to a pipe or truss using standard theatrical C clamps The Unit is provided with holes on each side of the case cover for attaching the C clamps and with a hole in the left edge of the case cover for a safety cable When mounting the PDS 750 TR in this way all necessary c...

Page 11: ...ddress the second light as the CTI min zapi will only address units as CK Light 1 2 Stand Alone features are not available with Ver 1 04 software Version 1 04a This is a low noise version that is otherwise identical in operation to 1 04 With version 1 04a the PDS 750 only outputs level changes to the fixture ports Since the CB fixtures hold the last the valid level data level sent until they recei...

Page 12: ...igurable fade and chase routines for stand alone operation In Stand Alone Mode selected routine is output to DMX Pass Thru for synchronized Stand Alone operation of many CB Supply systems DMX 512 Interface DMX Input via 5P XLR Male Isolated and repeated DMX Pass Thru via 5P XLR Female DMX Address interface utilizing 3 Rotary BCD Switches for DMX Address configuration CK Output Configuration 12 out...

Reviews: