11) Unit status request command (Cr)
Function
Requests the status.
Transmission format
(PC
→
display unit)
1
7
C
r
<CH>
C
R
L
F
Reply format
(Display unit
→
PC)
1
10
C
r
<CH>
<Status 1>
<Status 2>
<Error 1>
19
<Error 2>
<Error 3>
<Error 4>
C
R
L
F
Data details
CH:
01 (fixed)
Status code 1
D7:
fixed to 0
D6:
fixed to 0
D5:
fixed to 1
D4:
fixed to 1
D3:
* Not defined
D2:
Parameter editing
(0 = not executed, 1 = executing)
D1:
ABS display (0 = reset, 1 = ABS)
D1:
* Not defined
Status code 2
D7:
fixed to 0
D6:
fixed to 0
D5:
fixed to 1
D4:
fixed to 1
D3:
* Not defined
D2:
* Not defined
D1:
Hold state (0 = OFF, 1 = ON)
D0:
SET No. external specification
(1 = Specified externally)
Error code 1
D7:
fixed to 0
D6:
fixed to 0
D5:
fixed to 1
D4:
fixed to 1
D3:
[Err110] Detector type error
D2:
[Err200] Parameter R/W error
D1:
* Not defined
D0:
* Not defined
Error code 2
D7:
fixed to 0
D6:
fixed to 0
D5:
fixed to 1
D4:
fixed to 1
D3:
[Err100] Detector not connected
D2:
[Err130] Detector communication error
D1:
* Not defined
D0:
[Err***] Detector coordinate value error