9-1 Main Specifications
No.
Item
Details
1
Product model
SA-CD1N
SA-CD1N/BO
SA-CD1N/RS
2
Power voltage
12 to 24 VDC
±
10%
3
Consumption
current
200 mA or less (when connected to detectors)
4
Indicator
Polarity, 6 digits, mode display, LCD with green/red backlight
5
Display resolution
0.1
µ
m/1
µ
m/10
µ
m
6
Display range
−
99.9999 to 99.9999 mm
7
Quantization error
±
1 digit
8
Sensor head input
number
1 ch
9
Sensor head
supply voltage
5 VDC
±
10%
10
Reset function
Can be reset from any position
(by key, external signal, and RS commands)
11
Preset function
Polarity and 6 digits
12
Data hold
Indications and data held by external signals
13
Peak hold
+P,
−
P, P
−
P, P
−
P/2 (set using key and RS commands)
14
Measurement
direction switch
+/
−
(switchable setting)
15
Error function
Equipped
16
Pass / fail
judgment
−
NG/OK/NG
17
Measurement
conditions
registration
7 types (key and RS commands)
18
BCD
None
Equipped
None
19
RS-232C
None
None
Equipped
20
Input signal
Reset/hold/peak clear
21
Output signal
−
NG/OK/+NG/Error
22
Operating ambient
temperature
0 to 50
°
C (provided there is no condensation or freezing)
When storing:
−
10 to +60
°
C
23
Operating ambient
humidity
35 to 85% RH, When storing: 35 to 85% RH
24
Resistance to
vibration
10 to 150 Hz, double amplitude of 0.75 mm, or acceleration of 48 m/s
2
(switching frequency: 58 Hz)
Two hours each in the X, Y, and Z directions
25
Materials
Outer surface: polyester/Case: ABS
26
Weight
Approximately 60 g
Approximately 110 g
Approximately 110 g
Chapter
9
Specifications