- 37 -
Chapter
8
Troubleshooting
Chapter
1
Instructions for
Safe Use
Chapter
2
Product
Overview
Chapter
3
Connection and
Installation
Chapter
4
Names and
Functions
Chapter
5
Mode of Use
Chapter
6
Parameter
Settings
Chapter
7
External Input and
Output
右ページ
Chapter
9
Specifications
7-4-3 Communication Command Format
1) Initial parameter setting command (Is)
Function
Sets the initial parameters.
Transmission
format
(PC
→
display unit)
If the initial parameter number is P02 or P07:
1
10
16
I
ai
s
<CH>
<Initial parameter
number>
<Parameter
data>
C
R
L
F
If the initial parameter number is other than P02 and P07:
1
10
12
I
ai
s
<CH>
<Initial parameter
number>
<Parameter
data>
C
R
L
F
Reply format
(Display unit
→
PC)
1
6
R
s
<Receipt acknowledgment code>
C
R
L
F
Data details
CH:
01 (fixed)
Initial parameter number: 01 to 99 (refer to parameter)
Parameter data P02:
00.01 to 99.99
P03:
0 = 0.1, 1 = 1, 2 = 10 (
µ
m)
P04:
0 = 2-OFF, 1 = 2-ON
P06:
0 = Communication command,
1 = Internal timer
P07:
00.01 to 99.99 (sec)
P08:
0 = Er-OFF, 1 = Er-ON
P51:
001 to 256
P98:
0 to 9 (9 for parameter initialization)
P99:
0 = Key lock OFF, 1 = ON
Chapter
7
External Input and
Output