CT-S310II Series Service Manual
(5) USB-linked power off status
Description:
When the host device connected via USB is turned off, the brightness of the
POWER LED decreases.
Recovery condition:
Recovered when the host device is turned on, or the power switch is turned
off or on.
POWER LED (green)
ERROR LED (red)
Lit (dark)
Not lit
(6) Data
receive
Description:
The POWER LED blinks when data exists in the receive buffer. The
presence of data is checked at certain intervals. Accordingly, when the
data size is small and is processed rapidly, the LED may not blink even if
the data has been received.
Recovery condition:
Recovered when the data in the receive buffer is processed and cleared.
POWER LED (green)
ERROR LED (red)
Not lit
Blinks at long intervals,
repeatedly.
*1 The buzzer will beep in the following cases:
When MSW5-1 (buzzer setting) is set to ON
When the cover open or paper end error occurs (depending the MSW10-6 (buzzer event)
setting)
- 30 -
Summary of Contents for CT-S310II
Page 1: ...Service Manual COMPACT LINE THERMAL PRINTER CT S310II Revision 1 00 2011 4 25...
Page 2: ......
Page 45: ...CT S310II Series Service Manual 3 2 Part s Layout 3 2 1 SA MAIN PCB 30 43...
Page 47: ...CT S310II Series Service Manual 4 1 2 Main Control Board CPU2 DAC 45...
Page 48: ...CT S310II Series Service Manual 4 1 3 Main Control Board ROM 16M 64M 46...
Page 49: ...CT S310II Series Service Manual 4 1 4 Main Control Board RAM 47...
Page 50: ...CT S310II Series Service Manual 4 1 5 Main Control Board HEAD OP PANEL 48...
Page 51: ...CT S310II Series Service Manual 4 1 6 Main Control Board PF MOTOR CUTTER DRAWER 49...
Page 52: ...CT S310II Series Service Manual 4 1 7 Main Control Board SENSOR BUZZER 50...
Page 53: ...CT S310II Series Service Manual 4 1 8 Main Control Board POWER 51...
Page 54: ...CT S310II Series Service Manual 4 1 9 Main Control Board RS232C I F USB I F 52...