6
Chapter 6
Interfaces
40
Pin No.
Signal Name
Direction
Function
When this signal goes “Low,” the printer becomes
BUSY. It is initialized after all the data are printed.
31
*INIT
IN
BUSY is not cleared until this signal goes “High.”
A pulse width of 1
µ
sec or longer is required at the
receiving end.
(See “When Receiving the INIT Signal.”)
32
*FAULT
OUT
This signal indicates that the printer is in the error state.
It goes “Low” under any one of the following condi-
tions.
• Paper End
• When an abnormal operation is detected.
33
GND
Signal line ground.
34
DRAWER
KICK
OUT
The drawer kick connector's status signal is output.
STATUS
35
FUSE
OUT
Connected to +5 V through a 3.3k ohm resistor.
36
Not used.
•
IN indicates signals from the Host to the printer, and OUT indicates signals from the
printer to the Host.
* means negative logic signals.
Summary of Contents for CBM-262 Type II
Page 1: ...User sManual LINE THERMAL PRINTER CBM 262 MODEL ...
Page 41: ...6 31 Chapter 6 Interfaces Serial Interface Parallel Interface Drawer Kick Connector ...
Page 53: ...6 43 Drive Circuit 1 2 3 4 5 6 1 5A 24V Drawer Kick Connector ...
Page 54: ...6 Chapter 6 Interfaces 44 ...
Page 55: ...7 45 Chapter 7 Print Control Codes List of Control Codes Input Data Format ...
Page 116: ...7 Chapter 7 Print Control Codes 106 ...
Page 118: ...8 Chapter 8 Character Code Tables 108 Code Page ...
Page 119: ...8 109 Code Page ...
Page 120: ...8 Chapter 8 Character Code Tables 110 ...
Page 121: ...8 111 Japanese Code Table Japanese Code Table ...
Page 130: ...9 Chapter 9 Appendix 120 External View 12 359 162 ...