(How to set)
Set the alarm when <Depth Alarm> is displayed. Each push of the (R)(upper
right) button increases the figure by one. Quick forwarding of the setting is
possible by continuously pushing the same button.
Alarm depth can be set at intervals of 1m (3ft). If the alarm depth is set at
80m(260ft), the depth alarm mode will return to --(---).
When the depth alarm mode is –(--), the buzzer does not sound.
To stop the buzzer, push either the (S)(upper left), (R)(upper right) or
(M)(lower left) buttons.
C. Dive Time Memory (what is the dive time memory)
•
It is time needed for diving at a depth of more than 1m(3ft), which is
automatically memorized. As long as the depth meter mode is not cancelled,
the dive time is automatically added and memorized.
•
The dive time is displayed by changing over to the dive time memory mode
after finishing the dive
•
The dive time memory mode is replaced by the depth meter mode.
When more than 1m(3ft) in depth is measured, the dive time memory mode is
reset and the new value of the dive time is memorized.
However, when the measured depth is under 1m(3ft), it is not reset.
How to read the display
Dive time up to 59 min, 59 sec, is memorized at
intervals of 1 second. After memorizing 59 min,
59 sec, the display begins again with 00 min and
00 sec.
Return to Table of Contents
Return to Table of Contents