![Citel EXTender PBXgateway Administrator'S Manual Download Page 61](http://html1.mh-extra.com/html/citel/extender-pbxgateway/extender-pbxgateway_administrators-manual_2609643061.webp)
IP Dual Port PBXgateway and Remote System Administrator’s Guide
61
6 O
THER
MI
P
ARAMETERS
This chapter discusses background information for other parameters within the
Management Console (MC). These parameters are primarily used during trouble shooting
and the administrator would be instructed by a Customer Support representative on their
usage. The optional parameters are listed in alphabetical order.
Begin Test (IP)
Path
Gateway (Remote) ->Utilities->Diagnostics->Test IP
Description
A test that can be performed that ensures IP
communication is working correctly.
Usage
Same as the MS-DOS “Ping” command, it sends packets
back and forth to the unit specified by the IP Address
parameter field (directly below the Begin Test
parameter). After the test is complete messages
describing the results will be presented
Dependencies
none
Clear Log
Path Gateway
(Remote) ->Utilities->System
Description
Clears the log buffer of events on the PBXgateway
and/or the Remote.
WARNING:
Clearing the log cannot be undone.
Messages are permanently removed.
Usage
Used during trouble shooting. It clears the log of any
unnecessary log messages when tracking issues.
Dependencies
none
Dump All
Path Gateway
(Remote) ->Utilities->System
Description
This parameter will “dump” the entire log file to the
screen to allow a terminal emulation program (i.e.
HyperTerminal) to capture the text.
Usage
Allows the administrator to capture logs and system
information should an anomaly occur.
Dependencies
A VT100 terminal emulation program on a PC must be
running and have the capability of transferring the data
to a text file.
Edit Config
Path
Gateway (Remote) ->Utilities->File
Description
This is a file saved within the flash file system. It contains
all the configuration parameters of the Management
Console (MC). Changes can be saved without affecting
the currently running software image.
Usage
Used for managing multiple sites. The same
configuration file can be transferred to different units if
the programming is consistent between devices.
Dependencies
Must use the correct file type (i.e. runtime.cfg)
Document Number: M-4100-MUC
Version: Rev AA