Page 19
S6162-BS-MMC-010/12489
DRYER AIR FLOW INSTALLATION
Nothing
is
more
important
than
air
flow
for
the
proper
operation
of
a
clothes
dryer.
A dryer is
a pump which draws make-up air from the out-of-doors, through the heater, through the
clothes and then forces the air through the exhaust duct back to
the out-of-doors.
Just as
in
a
fluid
water
pump,
there
must
be
a
fluid
air
flow
to
the
inlet
of
the
dryer,
if
there
is
to
be
the
proper
fluid
air
flow
out
of
the
exhaust
duct.
In summary, there must be the proper size out-of-doors inlet air opening (4-6 times the
combined areas of the air outlet) and an exhaust duct, size and length of which allows flow
through the dryer with no more than 0.3 inches water column static pressure in the exhaust
duct.
In
some
instances,
special
fans
are
required
to
supply
make-up
air,
and/or
boost
exhaust
fans
are required for both regular and energy saving models.
FOR BEST DRYING:
1. Exhaust duct maximum length 14 feet of straight duct and maximum of two 90° bends.
2. Use 45° and 30° elbows wherever possible.
3. Exhaust each dryer separately.
4. Do not
install
wire
mesh
or
other
restrictions
in
the
exhaust
duct.
5. Use clean-outs in the exhaust duct and clean periodically when needed.
6. Never exceed 0.3 inches water column static pressure in the exhaust duct.
7. Inside surface of the duct must be smooth.
8. Recommend pop rivets for duct assembly.
FOR BEST DRYING:
1. Provide
opening
to
the
out-of-doors
in
accordance
with
the
following:
For each dryer -
8 inches diameter exhaust requires 2 square feet make-up air.
12 inches diameter exhaust requires 4 square feet make-up air.
2. Use
barometric
shutters
in
the
inlet
air
opening
to
control
air
when
dryers
are
not
running.
O T H E R R E C O M M E N D A T I O N S
To
assure
compliance,
consult
local
building
code
requirements.
T R O U B L E S H O O T I N G
Hot
dryer
surfaces,
scorched
clothes,
slow
drying,
lint
accumulations,
or
air
switch
malfunction
are
indicators
of
exhaust
duct
and/or
make-up
air
problems.
Summary of Contents for L36TD30ME
Page 10: ...Page 10 S6162 BS MMC 010 12489...
Page 20: ...Page 20 S6162 BS MMC 010 12489 RECOMMENDED STEAM PIPING INSTALLATION ILLUSTRATION...
Page 40: ...Page 40 S6162 BS MMC 010 12489 BACK CHANNEL BOLTED ASSEMBLY TU10600...
Page 50: ...Page 50 S6162 BS MMC 010 12489...
Page 51: ...Page 51 S6162 BS MMC 010 12489...
Page 52: ...Page 52 S6162 BS MMC 010 12489...
Page 53: ...Page 53 S6162 BS MMC 010 12489...