Page 20
The size of the gas service pipe is dependant upon many variables,
such as tees, lengths, etc. Specific pipe size should be obtained from
the gas supplier. Refer to the “Gas Pipe Size” chart in this manual for
general gas pipe size information.
CAUTION: Gas loop piping must be installed as illustrated
to maintain equal gas pressure for all dryers connected to a
single gas service
Other gas-using appliances should be connected upstream
from the loop.
WARNING:
LIQUIFIED PETROLEUM GASES ONLY !
A gas pressure regulator for liquified petroleum gases is not
furnished on gas heated clothes dryers. This regulator is normally
furnished by the installer. In accordance with American Gas
Association (AGA) standards, a gas pressure regulator, when
installed indoors, must be equipped with a vent limiter or a vent line
must be installed from the gas pressure regulator vent to the outdoors.
Gas Service Installation Instructions
GAS SERVICE
INSTALLATION
INSTRUCTIONS
GAS PRESSURE
REGULATOR FOR
LIQUIFIED
PETROLEUM GASES
Summary of Contents for L28UR30E
Page 10: ...Page 10 L28UR30 Outline Dimensions Gas Steam and Electric Models...
Page 11: ...Page 11 L28US30 Outline Dimensions Gas Model...
Page 23: ...Page 23 Steam Piping Installation Illustration...
Page 40: ...Page 40 DIRECTSPARK IGNITIONOPERATION FLOW CHART...
Page 49: ...Page 49 30 lb Dryer Front View Illustration...
Page 51: ...Page 51 30 lb Dryer Rear View Illustration...
Page 64: ...Page 64...