Page 24
Dryer Installation With Multiple Exhaust
For Exhaust Duct less than 14 feet (4.3 m) and 2 elbows equivalent
and less than 0.3 inches (7.6 mm) water column static pressure.
_ _ _ _
_ _ _ _
_ _ _ _
_ _ _ _
_ _ _ _
_ _ _ _
AUTOMATIC ELECTRICAL CONTROL FOR EXHAUST FAN
For one or more dryers to start fan.
Exhaust
Booster Fan
Power Supply
to Fan
Relay Coils
Start and Stop
Switches on
Dryers
DRYER EXHAUSTS
Area of section “A-A” must be equal to the sum of dryer exhaust pipes entering
multiple exhaust pipe. (See chart below.)
MODELS: L28FD30, L28US30, L36FD30, L36US30, L36US36, L44FD42
MODELS: L28CD30, L28UR30, L36CD30, L36UR30, L36UR36, L36AR36, L44FD42
MODELS: L44CD42, L50CD42
No. of dryers
Duct diameter
(in inches)
(in cm)
No. of dryers
Duct diameter
(in inches)
(in cm)
No. of dryers
Duct diameter
(in inches)
(in cm)
1
2 3
4
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
6
9 11 12 14 15 16 17 18 19 20 21 22 23 23 24 25 26 26 27 28 28 29 30
15 23 27 30 35 38 41 43 46 48 51 53 56 58 58 61 63 66 66 68 71 71 73 76
1
2 3
4
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
8 12 14 16 18 20 22 23 24 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40
20 30 25 41 46 51 56 58 61 66 68 71 73 76 78 81 84 86 89 91 94 97 99 100
1
2 3
4
5
6
7
8
9 10 11 12
12 17 21 24 27 30 32 34 36 38 40 42
30 43 53 61 68 76 81 86 91 97 100 106
Summary of Contents for L28UR30E
Page 10: ...Page 10 L28UR30 Outline Dimensions Gas Steam and Electric Models...
Page 11: ...Page 11 L28US30 Outline Dimensions Gas Model...
Page 23: ...Page 23 Steam Piping Installation Illustration...
Page 40: ...Page 40 DIRECTSPARK IGNITIONOPERATION FLOW CHART...
Page 49: ...Page 49 30 lb Dryer Front View Illustration...
Page 51: ...Page 51 30 lb Dryer Rear View Illustration...
Page 64: ...Page 64...