Page 33
1. This control is equipped with two banks of four DIP switches.
2. Each DIP switch bank consists of 4 small switches each with a
specified amount of time (minutes), as shown:
3. To set the time on the DIP bank simply set the appropriate
switch to the ON (up) position to total the desired amount of
time.
NOTE
OFF (down) position equals 0 minute.
EXAMPLE: 25¢ for 12 minutes
MINUTES: 0 + 0 + 4 + 8 = 12 min.
Setting Time On Computerized Coin Meter
ON
1 min.
2 min.
4 min.
8 min.
OFF
INSTRUCTIONS FOR
SETTING TIME ON
COMPUTERIZED COIN
METER