background image

Trouble Shooting Cont.

Press Will Not Work Automaticly (“AOL” Only):

1.)  Auto/Manual Switch Set To Manual or Defective.

2.)  Relay #9 Not Activated.

3.)  Check All Timers Are Plugged In Completely.

No Automatic Head Steam (“AOL” Only):

1.)  Head Steam Solenoid Valve #3 Not Activated or Defective.

2.)  Steam Timer T1 In Zero (0) Position.

3.)  Head Steam Cylinder Not Activated or Kinked Air Line From Air Valve #3 To

       Air Cylinder #20.

4.)  “O” Ring In Air Cylinder #20 Leaking.

5.)  Air Cylinder #20 Out Of Adjustment.

No Pause Between Steam and First Vacuum (“AOL” Only):

1.)  Dwell Timer T2 Set At Zero (0) or Defective.

No First Vacuum (“AOL” Only):

1.)  First Vacuum Timer T3 Set At Zero (0) or Defective.

2.)  Vacuum Valve Solenoid Not Being Activated or Defective.

3.)  Vacuum Air Cylinder #19 Not Being Activated.

4.)  Kinked Air Line To Air Cylinder #19.

5.)  Defective Vacuum Air Cylinder #19.

No Slow Opening (“AOL” Only):

1.)  Slow Opening Timer T4 Set To Zero (0) or Defective.

2.)  Needle Valve #25 Open To Far.

3.)  Air Regulator #15 Out Of Adjustment. (Set to 50 PSI or 4 Bars)

No End Vacuum (“AOL” Only):

1.)  End Vacuum Timer T5 Set To Zero (0) or On The Same Setting As

       Slow Opening Timer T4.

2.)  End Vacuum Timer T5 Defective.

Head Closes To Slow:

1.)  Flow Control Air Valve #24 Almost Closed.

Head Opens To Fast:

1.)  Air Regulator #15 Open Too Much.

Head Opens To Fast When Activating Emergency Stop:

1.)  Needle Valve W/Filter #27 Open Too Much.

Not A Good Crease:

1.)  Steam and Vacuum Time Too Short. (“AOL” Only)

2.)  Not Enough Steam In Head or Buck (Adjust Steam Valve Screws)

3.)  Vacuum Too Weak.

4.)  Bad Padding.

5.)  Head and Buck Out Of Adjustment.

6.)  Buck Steam Leaking Causing Wet Padding.

                                                                                  

Page 8

Summary of Contents for AOLAUKMAN592

Page 1: ...TROUBLE SHOOTING GUIDE AOL and AU PRESSES CISSELL MANUFACTURING COMPANY HEADQUARTERS PHONE 502 587 1292 831 SOUTH FIRST ST SALES FAX 502 585 3625 P O BOX 32270 SERVICE PARTS FAX 502 681 1275 LOUISVIL...

Page 2: ...utlet 3 8 NPT Air Inlet AOL AU 3 8 NPT Air Vacuum Connection 2 NPT Domestic Shipping Weight approx AOL 574 lbs 260 kg AU 570 lbs 259 kg MU 635 lbs 288 kg Electrical Requirements AOL AU 12OV 50 6O Hz 1...

Page 3: ...am piping procedure The connections are tagged If there are any questions about the connections refer to the DETAIL LINE DRAWINGS Page 5 The steam must be connected to the machine in such way that the...

Page 4: ...CK BOTTOM STEAM To apply bottom buck steam depress the Steam Foot Switch TIMERS There are five timers for the automatic cycle Timer Tl is for automatic head steam usually set at 2 1 2 to 3 seconds Tim...

Page 5: ...p giving unequal pressure and poor quality We recommend cleaning the combination pads those with sponge rubber inserts every two weeks by making heavy suds with a clothes type detergent Wisk etc and s...

Page 6: ...Page 5...

Page 7: ...Activating CANCEL 1 Relays 5 or 8 Not Plugged In Completely 2 Defective CANCEL Switch air 12 3 Defective CANCEL Pressure Switch 4 Defective Air Valve 22 5 Head Open Closing Air Valve 6 Not Activated...

Page 8: ...Out Of Adjustment 2 Buck Steam Foot Switch Not Working or Defective 3 Buck Steam Air Valve 1 Defective 4 Air Line From Air Valve 1 To Air Cylinder 18 Kinked Buck Steam Leaking 1 Buck Steam Valve Seat...

Page 9: ...ed or Defective 3 Vacuum Air Cylinder 19 Not Being Activated 4 Kinked Air Line To Air Cylinder 19 5 Defective Vacuum Air Cylinder 19 No Slow Opening AOL Only 1 Slow Opening Timer T4 Set To Zero 0 or D...

Reviews: