Trouble Shooting Cont.
Press Will Not Work Automaticly (AOL Only):
1.) Auto/Manual Switch Set To Manual or Defective.
2.) Relay #9 Not Activated.
3.) Check All Timers Are Plugged In Completely.
No Automatic Head Steam (AOL Only):
1.) Head Steam Solenoid Valve #3 Not Activated or Defective.
2.) Steam Timer T1 In Zero (0) Position.
3.) Head Steam Cylinder Not Activated or Kinked Air Line From Air Valve #3 To
Air Cylinder #20.
4.) O Ring In Air Cylinder #20 Leaking.
5.) Air Cylinder #20 Out Of Adjustment.
No Pause Between Steam and First Vacuum (AOL Only):
1.) Dwell Timer T2 Set At Zero (0) or Defective.
No First Vacuum (AOL Only):
1.) First Vacuum Timer T3 Set At Zero (0) or Defective.
2.) Vacuum Valve Solenoid Not Being Activated or Defective.
3.) Vacuum Air Cylinder #19 Not Being Activated.
4.) Kinked Air Line To Air Cylinder #19.
5.) Defective Vacuum Air Cylinder #19.
No Slow Opening (AOL Only):
1.) Slow Opening Timer T4 Set To Zero (0) or Defective.
2.) Needle Valve #25 Open To Far.
3.) Air Regulator #15 Out Of Adjustment. (Set to 50 PSI or 4 Bars)
No End Vacuum (AOL Only):
1.) End Vacuum Timer T5 Set To Zero (0) or On The Same Setting As
Slow Opening Timer T4.
2.) End Vacuum Timer T5 Defective.
Head Closes To Slow:
1.) Flow Control Air Valve #24 Almost Closed.
Head Opens To Fast:
1.) Air Regulator #15 Open Too Much.
Head Opens To Fast When Activating Emergency Stop:
1.) Needle Valve W/Filter #27 Open Too Much.
Not A Good Crease:
1.) Steam and Vacuum Time Too Short. (AOL Only)
2.) Not Enough Steam In Head or Buck (Adjust Steam Valve Screws)
3.) Vacuum Too Weak.
4.) Bad Padding.
5.) Head and Buck Out Of Adjustment.
6.) Buck Steam Leaking Causing Wet Padding.
Page 8
Summary of Contents for AOLAUKMAN592
Page 6: ...Page 5...