background image

Trouble Shooting Cont.

Head Will Not Stop In 60 Degree Position:

1.)  Defective Head Position Reed Switch #2 (L2) or Out Of Adjustment.

2.)  Defective Head Position Switch (Electrical)

3.)  Relay #8 Defective or Loose.

Head Will Not Stop At 110 Degree Postion:

1.)  Defective Head Position Reed Switch #3 (L3) or Out Of Adjustment.

2.)  Defective Head Position Switch (Electrical)

3.)  Relay #8 Defective or Loose.

No Head Steam Manual Position:

1.)  Adjusting Screw Is Not Activating Plunger On Rear Of Steam Valve.

Head Steam Leaking:

1.)  Debris On Seat In Head Steam Valve.

2.)  Spring In Head Valve Broken or Weak.

No Buck Stem:

1.)  Buck Steam Valve Out Of Adjustment.

2.)  Buck Steam Foot Switch Not Working or Defective.

3.)  Buck Steam Air Valve #1 Defective.

4.)  Air Line From Air Valve #1 To Air Cylinder #18 Kinked.

Buck Steam Leaking:

1.)  Buck Steam Valve Seat Dirty or Defective.

2.)  Spring In Buck Valve Broken or Weak.

3.)  Buck Steam Solenoid #1 Leaking Through Holding The Valve Open.

4.)  Buck Steam Foot Switch Stuck Closed Holding Valve Open.

No Vacuum Switch Manual:

1.)  Vacuum Foot Switch Not Activited or Defective.

2.)  Vacuum Air Valve #2 Defective.

3.)  Vacuum Air Cylinder #19 defective.

4.)  Kinked Air Line From Air Valve #2 To Air Cylinder #19.

Vacuum All The Time:

1.)  Vacuum Valve Leaking or Stuck Open.

Buck Padding Getting Wet:

1.)  Steam Pressure Too Low.

2.)  Steam Trap Not Working.

3.)  Leaking Vacuum Valve.

Head Steam Too Wet:

1.)  Steam Pressure Too Low.

2.)  Steam Trap Not Working.

                                                                                   

Page 7

Summary of Contents for AOLAUKMAN592

Page 1: ...TROUBLE SHOOTING GUIDE AOL and AU PRESSES CISSELL MANUFACTURING COMPANY HEADQUARTERS PHONE 502 587 1292 831 SOUTH FIRST ST SALES FAX 502 585 3625 P O BOX 32270 SERVICE PARTS FAX 502 681 1275 LOUISVIL...

Page 2: ...utlet 3 8 NPT Air Inlet AOL AU 3 8 NPT Air Vacuum Connection 2 NPT Domestic Shipping Weight approx AOL 574 lbs 260 kg AU 570 lbs 259 kg MU 635 lbs 288 kg Electrical Requirements AOL AU 12OV 50 6O Hz 1...

Page 3: ...am piping procedure The connections are tagged If there are any questions about the connections refer to the DETAIL LINE DRAWINGS Page 5 The steam must be connected to the machine in such way that the...

Page 4: ...CK BOTTOM STEAM To apply bottom buck steam depress the Steam Foot Switch TIMERS There are five timers for the automatic cycle Timer Tl is for automatic head steam usually set at 2 1 2 to 3 seconds Tim...

Page 5: ...p giving unequal pressure and poor quality We recommend cleaning the combination pads those with sponge rubber inserts every two weeks by making heavy suds with a clothes type detergent Wisk etc and s...

Page 6: ...Page 5...

Page 7: ...Activating CANCEL 1 Relays 5 or 8 Not Plugged In Completely 2 Defective CANCEL Switch air 12 3 Defective CANCEL Pressure Switch 4 Defective Air Valve 22 5 Head Open Closing Air Valve 6 Not Activated...

Page 8: ...Out Of Adjustment 2 Buck Steam Foot Switch Not Working or Defective 3 Buck Steam Air Valve 1 Defective 4 Air Line From Air Valve 1 To Air Cylinder 18 Kinked Buck Steam Leaking 1 Buck Steam Valve Seat...

Page 9: ...ed or Defective 3 Vacuum Air Cylinder 19 Not Being Activated 4 Kinked Air Line To Air Cylinder 19 5 Defective Vacuum Air Cylinder 19 No Slow Opening AOL Only 1 Slow Opening Timer T4 Set To Zero 0 or D...

Reviews: