background image

                     

OPERATING INSTRUCTIONS

ON-OFF SWITCH

The “On-Off Switch” must be on.

AUTOMATIC MANUAL SWITCH

The “Automatic Manual Switch” must be to the right for the press to be in the automatic cycle.

CLOSING PRESS HEAD

The “Close Switch” must be depressed to close the press head.

LOCK PRESS HEAD CLOSED

To lock the press head closed the “Lock Switch” must be depressed while depressing the “Close

Switch.”

HEAD RELEASE

The press head can be released two ways, manually or automatically. To release manually, depress

the “Cancel Switch.” The head will release at the time the “Cancel Switch” is actuated. If the ma-

chine is in automatic, it will reset for another cycle.

HEAD (TOP) STEAM

To apply steam manually push down on the head steam valve handle. When the handle is released

the steam will shut off. Automatic head steam is applied when the press is in the automatic cycle and

the “Lock Switch” is released.

BUCK (BOTTOM) STEAM

To apply bottom buck steam depress the “Steam Foot Switch.”

TIMERS

There are five timers for the automatic cycle.

Timer Tl is for automatic head steam usually set at 2 - 1/2" to 3 seconds.

Timer T2 is for the dwell time between steam and first vacuum usually set at 2 seconds

Timer T3 controls 3 different operations. The first operation T3 controls is the first vacuum and is

usually set at 2 to 3 seconds. Timer T3 also energizes Timers T4 and T5 after the first vacuum is

completed.

Timer T4 controls the release of the press head and also determines when the second vacuum begins.

The head lift speed control valve #8 in back of Solenoid Valve SV3 controls the speed of the press

head as it begins to lift off the buck to prevent vacuum pick-up of the garment. Timer T4 should be

set at 1 to 2 seconds depending on where the head lift speed control valve is set.

Timer T5 controls the length of the second vacuum and ends the automatic cycle. Timer T5 must be

set higher than Timer T4 in order to get second vacuum. Timer T5 should be set at about 5 to 6

seconds.

Page 3

Summary of Contents for AOLAUKMAN592

Page 1: ...TROUBLE SHOOTING GUIDE AOL and AU PRESSES CISSELL MANUFACTURING COMPANY HEADQUARTERS PHONE 502 587 1292 831 SOUTH FIRST ST SALES FAX 502 585 3625 P O BOX 32270 SERVICE PARTS FAX 502 681 1275 LOUISVIL...

Page 2: ...utlet 3 8 NPT Air Inlet AOL AU 3 8 NPT Air Vacuum Connection 2 NPT Domestic Shipping Weight approx AOL 574 lbs 260 kg AU 570 lbs 259 kg MU 635 lbs 288 kg Electrical Requirements AOL AU 12OV 50 6O Hz 1...

Page 3: ...am piping procedure The connections are tagged If there are any questions about the connections refer to the DETAIL LINE DRAWINGS Page 5 The steam must be connected to the machine in such way that the...

Page 4: ...CK BOTTOM STEAM To apply bottom buck steam depress the Steam Foot Switch TIMERS There are five timers for the automatic cycle Timer Tl is for automatic head steam usually set at 2 1 2 to 3 seconds Tim...

Page 5: ...p giving unequal pressure and poor quality We recommend cleaning the combination pads those with sponge rubber inserts every two weeks by making heavy suds with a clothes type detergent Wisk etc and s...

Page 6: ...Page 5...

Page 7: ...Activating CANCEL 1 Relays 5 or 8 Not Plugged In Completely 2 Defective CANCEL Switch air 12 3 Defective CANCEL Pressure Switch 4 Defective Air Valve 22 5 Head Open Closing Air Valve 6 Not Activated...

Page 8: ...Out Of Adjustment 2 Buck Steam Foot Switch Not Working or Defective 3 Buck Steam Air Valve 1 Defective 4 Air Line From Air Valve 1 To Air Cylinder 18 Kinked Buck Steam Leaking 1 Buck Steam Valve Seat...

Page 9: ...ed or Defective 3 Vacuum Air Cylinder 19 Not Being Activated 4 Kinked Air Line To Air Cylinder 19 5 Defective Vacuum Air Cylinder 19 No Slow Opening AOL Only 1 Slow Opening Timer T4 Set To Zero 0 or D...