OPERATING INSTRUCTIONS
ON-OFF SWITCH
The On-Off Switch must be on.
AUTOMATIC MANUAL SWITCH
The Automatic Manual Switch must be to the right for the press to be in the automatic cycle.
CLOSING PRESS HEAD
The Close Switch must be depressed to close the press head.
LOCK PRESS HEAD CLOSED
To lock the press head closed the Lock Switch must be depressed while depressing the Close
Switch.
HEAD RELEASE
The press head can be released two ways, manually or automatically. To release manually, depress
the Cancel Switch. The head will release at the time the Cancel Switch is actuated. If the ma-
chine is in automatic, it will reset for another cycle.
HEAD (TOP) STEAM
To apply steam manually push down on the head steam valve handle. When the handle is released
the steam will shut off. Automatic head steam is applied when the press is in the automatic cycle and
the Lock Switch is released.
BUCK (BOTTOM) STEAM
To apply bottom buck steam depress the Steam Foot Switch.
TIMERS
There are five timers for the automatic cycle.
Timer Tl is for automatic head steam usually set at 2 - 1/2" to 3 seconds.
Timer T2 is for the dwell time between steam and first vacuum usually set at 2 seconds
Timer T3 controls 3 different operations. The first operation T3 controls is the first vacuum and is
usually set at 2 to 3 seconds. Timer T3 also energizes Timers T4 and T5 after the first vacuum is
completed.
Timer T4 controls the release of the press head and also determines when the second vacuum begins.
The head lift speed control valve #8 in back of Solenoid Valve SV3 controls the speed of the press
head as it begins to lift off the buck to prevent vacuum pick-up of the garment. Timer T4 should be
set at 1 to 2 seconds depending on where the head lift speed control valve is set.
Timer T5 controls the length of the second vacuum and ends the automatic cycle. Timer T5 must be
set higher than Timer T4 in order to get second vacuum. Timer T5 should be set at about 5 to 6
seconds.
Page 3
Summary of Contents for AOLAUKMAN592
Page 6: ...Page 5...