1-16
Cisco uBR10012 Universal Broadband Router Hardware Installation Guide
OL-18259-09
Chapter 1 Cisco uBR10012 Universal Broadband Router Overview
Cisco uBR10012 Universal Broadband Router Modules
way that the power connections reside facing inside the rack when viewed from the front. This allows
the DC output terminals of the external AC-input power shelf to be on the same side as the DC-input
terminals of the Cisco uBR10012 chassis.
The Lineage AC-DC power shelf has two DC power sources, four AC-input power supply sources, and
J1 and J2 connectors. Each AC-input power supply module is automatically powered on when it is
plugged into the wall socket. (See
Figure 1-6)
.
Figure 1-6
Lineage AC-DC Power Shelf - Front and Rear View
All cable connections for AC-input power, DC-output power, and status signals are made from the rear
of the power shelf. Each AC power supply module has an individual AC facility cord attachment. All
four AC-input cords must be attached to the facility for all four AC power modules to function. Two
DC-interconnect cables provide DC-output power to the DC PEM (UBR10-PWR-DC=) modules on the
Cisco uBR10012 chassis. (See
Figure 1-7)
.
Note
The AC-input power cables, DC-output power cables, and alarm monitor cable are supplied along with
Lineage. We recommend that you use these cables for cabling the shelf to the Cisco uBR10012 router.
278055
3
4
2
2
1
1
Front view
Rear view
1
DC power source terminal blocks
3
J2 connector
2
AC input power connectors
4
J1 connector / alarm cable interface