A-2
Cisco uBR10012 Universal Broadband Router Hardware Installation Guide
OL-18259-09
Appendix A Technical Specifications
Cisco uBR10012 Chassis and Chassis Components
DC Power entry modules
(PEM)— 34-1651-04,
34-1651-05
Power supply monitoring
cable
Supports two separate input
feeds (–48 to –60VDC) by
means of built-in two-position
terminal blocks.
Part Number: UBR10-PWR-DC (Primary)
Part Number: UBR10-PWR-MON-CAB
Part Number: UBR10-PWR-MON-CAB= (Spare)
•
Dimensions
Height: 19.25 in (48.894 cm)
Width: 6 in. (15.24 cm)
Depth: 5 in. (12.4 cm)
•
Weight: 10 lbs. (4.54 kg)
•
Temperature range
Operating: 41
°
F to 104
°
F (5
°
C to 40
°
C)
Storage: -40
°
F to 158
°
F (-40
°
C to 70
°
C)
The Power output, DC input voltage and DC input current vary for the Cisco DC PEM entry
modules. See
Table 2-2 on page 2-8
.
DC Power entry modules
(PEM)—341-0388-01
Part Number: UBR10-PWR-DC-PLUS (Primary)
Part Number: UBR10-PWR-DC-PLUS= (Spare)
•
Dimensions:
Height: 19.25 in. (48.894 cm)
Width: 6 in. (15.24 cm)
Depth: 5 in. (12.4 cm)
•
Weight: 16 lbs. (7.25 kg)
•
DC-input Voltage: –48 to –60 VDC nominal
–40.5 to –72 VDC minimum to maximum
•
DC-input Current Connections: 50 A + 50 A
•
Power Output: 3300 W maximum
•
Temperature range:
Operating: 41
°
F to 104
°
F (5
°
C to 40
°
C)
Storage: -40
°
F to 158
°
F (-40
°
C to 70
°
C)
•
Relative Humidity:
Operating: 5% to 85%, non-condensing
Storage: 5% to 95%, non-condensing
•
Operating Altitude: –197 to 13,693 feet (–60 to 4000 m)
Table A-1
Cisco uBR10012 Router and Router Components Physical Specifications (continued)
Description