C-9
Cisco UCS C240 M4 Server Installation and Service Guide
OL-32474-01
Appendix C RAID Controller Considerations
RAID Controller Cabling
SFF 24-Drive Backplane with Expander Cabling
The SFF 24-drive option has a backplane and SAS expander.
Note
No cabling is required for the embedded SATA RAID controller to control the internal SSD boot drives.
Cisco UCS 12G Modular RAID Controller
This option can control up to 24 drives.
The required
UCS-240CBLMR24=
cable kit has one cable with a mini-SAS HD connector on each end.
Make the following connections:
1.
Connect one end of the cable to the modular RAID controller card.
2.
Connect the other end of the cable to the single mini-SAS HD connector on the expander.
Cisco UCS SAS 9300-8i HBA
This option can control up to 24 drives (non-RAID).
The required
240CBLHBA24=
cable kit has one cable with a mini-SAS HD connector on each end.
Make the following connections:
1.
Connect one end of the cable to the modular RAID controller card.
2.
Connect the other end of the cable to the single mini-SAS HD connector on the expander.
LFF 12-Drive Backplane with Expander
The LFF 12-drive option has a SAS expander integrated with the backplane.
Note
No cabling is required for the embedded SATA RAID controller to control the internal SSD boot drives.
Cisco UCS 12G Modular RAID Controller
This option can control up to 12 drives.
The required
UCS-240CBLMR12=
cable kit has one Y-cable with a mini-SAS HD double connector on
one end and two mini-SAS HD single connectors on the other end.
1.
Connect the mini-SAS double connector to the modular RAID controller card.
2.
Connect single connector PORT A to the PORT A connector on the backplane.
3.
Connect single connector PORT B to the PORT B connector on the backplane.
Cisco UCS SAS 9300-8i HBA
This option can control up to 12 drives (non-RAID).
The required
240CBLHBA12=
cable kit has one Y-cable with a mini-SAS HD double connector on one
end and two mini-SAS HD single connectors on the other end.
Make the following connections:
1.
Connect the mini-SAS double connector to the modular RAID controller card.
2.
Connect single connector PORT A to the PORT A connector on the backplane.
3.
Connect single connector PORT B to the PORT B connector on the backplane.
Summary of Contents for UCS C240 M4
Page 8: ...Contents viii Cisco UCS C240 M4 Server Installation and Service Guide OL 32474 01 ...
Page 12: ...xii Cisco UCS C240 M4 Server Installation and Service Guide OL 32474 01 ...
Page 14: ...xiv Cisco UCS C240 M4 Server Installation and Service Guide OL 32474 01 ...
Page 16: ...xvi Cisco UCS C240 M4 Server Installation and Service Guide OL 32474 01 ...
Page 26: ...1 10 Cisco UCS C240 M4 Server Installation and Service Guide OL 32474 01 Chapter 1 Overview ...