Figure 2-5
shows the location of the Wiegand interface connections. The table describes the connections
for 10-pin and 5-pin reader interface connections. The wire connectors from the reader device are shown
in parentheses. If attaching a second reader, use the alternative connections shown in the column on the
far right.
Figure 2-5
Wiegand Interface on the Gateway and Reader Modules
Chassis
Label
Description
One Reader
10 Wire Connection
First Reader in a
5 Wire Connection
Second Reader in a
5 Wire Connection
1
PWR +12v PWR
(red)
1
PWR
(red)
PWR
(red)
2
GND
Ground
GND (black)
GND (black)
GND (black)
3
D0 Data
0
D0
(green)
D0
(green)
----------
4
D1/CLCK
Data 1
D1/CLCK (white)
D1/CLCK (white)
----------
5
DRTN Shield DRTN
(shield)
DRTN
(shield)
DRTN
(shield)
6
GRN Output
2
GRN
(orange)
GRN
(orange)
----------
7
RED Output
RED
(brown)
----------
3
GRN
(orange)
8
BPR Output
(Beeper)
BPR
(yellow)
(yellow)
----------
----------
271603
10
9
8
7
6
5
4
3
2
1