Resetting the Cisco Physical Access Gateway
Resetting the Cisco Physical Access Gateway
Reset the Gateway to powercycle the module, restore the factory settings, or delete the stored logs and
other data. The effect of the restart depends on the type of restart your perform, as described in the
following sections. You can reset the module using the physical button on the side of the module, or in
software using either the web administration tool or the Hardware device view in Cisco PAM.
•
Soft Reset (Powercycle), page 2-25
•
Hard Reset (Restore Factory Defaults), page 2-25
Soft Reset (Powercycle)
Use the soft reset to powercycle the Cisco Physical Access Gateway. A soft reset reloads the device
firmware to clear any software issues, but does not impact stored data. The password, logs and other
information are retained.
Use one of the following methods to perform a soft reset:
•
Hardware reset button
: Press and release the reset button once. See
Figure 2-2 on page 2-3
for the
location of the
Reset
button.
•
Gateway web administration tool
: Follow the instructions in the
“Configuring and Managing the
Gateway Using a Direct Connection” section on page 2-15
to connect a PC to the Gateway, and click
the
Reset
button at the bottom of the screen.
•
Cisco PAM desktop software
: Open the
Hardware
module in the
Doors
menu and right-click on
a
Gateway Controller
(blue icon). Choose
Reset
from the menu.
Hard Reset (Restore Factory Defaults)
A hard reset deletes all information on the device (including log and event data) and resets the password
and all other configurations to the factory default. Any custom configurations previously entered on the
device are removed.
Note the following:
•
Allow five to 10 minutes for the hard reset erase operation to complete.
•
Do not disconnect power from the module until the hard reset erase process is complete. Loss of
power during a hard reset can result in equipment malfunction.
•
The SVR LED flashes throughout the erase operation.
•
The module reboots with the existing firmware image after the hard reset is complete.
Use one of the following methods to perform a hard reset:
•
Hardware reset button
: Press
Reset
button
three times in succession
. See
Figure 2-2 on page 2-3
for the location of the
Reset
button.
•
Gateway web administration tool
: Follow the instructions in the
“Configuring and Managing the
Gateway Using a Direct Connection” section on page 2-15
to connect a PC to the Gateway, and click
the
Restore Factory Defaults
button at the bottom of the screen.