4.1.2. Best practice for shielded CAT5/6 connectors
CAUTION
To avoid the possibility of damage to network components due
to electrostatic discharge (ESD), it is extremely important that
all shielded CAT5/6 connectors are assembled according to
the standards and directives in this section.
Figure 5. Shielded CAT5/6 connector
in
cables
RF-shielded
Use only professional-quality, outdoor-rated,
conjunction with Cisco radio transceivers.
Assemble all shielded CAT5/6 connectors to the following standards:
• Only use shielded RJ45 Ethernet connectors.
• When inserting each connector into a shielded Ethernet port, the
connector's inner jacket must form a positive contact with the
Ethernet port.
• When each RJ45 connector is plugged into the correct Ethernet
port of the Cisco FM3200 Base, lock the bottom of the RJ45
connector using the side retaining screws.
• When all RJ45 connectors are connected to the unit, make sure
that the bottom cover of the unit is correctly secured to the unit
enclosure.
4.1.3. Cisco FM3200 Base Status and link LEDs
Unit and link quality status
The front panel of the Cisco FM3200 Base (as seen below) contains
seven LEDs. The panel is used to check the unit status and wireless link
quality status.
Hardware installation