Configuring System Settings
OL-31980-01
233
6
From the
Enable/Disable
drop-down list, choose
Yes
and the alarm message will
be reported. Choose
No
and the alarm is disabled and the Relay and Trap
settings are ignored.
Note:
The
Enable/Disable
drop-down list must be set to Yes for the Relay and
Trap settings to be functional.
7
If current alarm is enabled, set
Trap
to Yes and the SNMP trap message will be
sent when the alarm is set or cleared.
Note:
No is a read only value that indicates the setting is Yes, but is currently
being suppressed because the alarm is disabled (Enb is set to No).
8
If current alarm is enabled, choose
Yes
from the
Relay
drop-down list for the
rear panel alarm relay to be triggered when the alarm is set or cleared.
Note:
No is a read only value that indicates the setting is Yes, but is currently
being suppressed because the alarm is disabled (Enb is set to No).
9
Click
Apply
.
To Set Up Warnings
Proceed as follows to set up the warning parameters:
1
From the Alarm Setup page, click on the
Warning Setup
link at the bottom left
hand corner of the page. The Warning Setup page is displayed.
2
Check the
Enable Alarm/Warning Front Panel Reminder
check box and the
warning flashes on the LCD display for a two-second interval every 10 seconds.
The warning will continue to flash periodically until it is either cleared or the
Enable Alarm/Warning Front Panel Reminder
is unchecked.
3
The
Warning Setup
area displays a list of the warning messages. For more
information on warning messages, refer to
D9859 Transcoder Alarm Messages
(on page 260).