32-4
Cisco BPX 8600 Series Installation and Configuration
Release 9.3.0, Part Number 78-10674-01 Rev. D0, July 2001
Chapter 32 BPX Switch Cabling Summary
LM-BCC Cabling
Modem Cabling
Refer to Chapter 15, Connecting Temporary Terminal and Attaching Peripherals, for modem cabling
information.
External Clock Input Cabling
This cabling is for making external clock connections for use by the BCC-32 and BCC-4 backcards.
The BCC-32 uses the BCC-bc backcard.
The discontinued BCC-3 and BCC-4 both use the BCC-3-bc backcard.
T1 Clock Cabling
Table 32-8 through Table 32-11 lists T1 clock cabling details.
Table 32-7 LAN Port Pin Assignments
Pin #
Name
Pin #
Name
1
Shield
---
---
2
Collision Pr
9
Collision Presence -
3
XMT +
10
XMT -
4
Reserved
11
Reserved
5
RCV +
12
RCV -
6
Power return
13
Power (+12V)
7
Reserved
14
Reserved
8
Reserved
15
Reserved
Table 32-8 External Clock Cabling
Cable Parameter
Description
Cable Type:
22 AWG, ABAM individually shielded twisted pair. Two pair per T1 line
(1 transmit and 1 receive).
Cable Connector:
Male DB-15 subminiature. See Table 32-10 through Table 32-11 for
pinouts.
Max. Cable Length:
533 ft (162 m.) maximum between the BPX switch and the first repeater
or CSU. Selection of cable length equalizers.
Table 32-9 T1 Connection to XFER TMG on BCC-bc
Pin #
Description
1
Transfer timing ring
Summary of Contents for BPX 8600 Series
Page 43: ...P A R T 1 The BPX Switch ...
Page 44: ......
Page 151: ...P A R T 2 Installation ...
Page 152: ......
Page 261: ...P A R T 3 Initial Configuration and Network Management ...
Page 262: ......
Page 291: ...P A R T 4 Configuring Connections ...
Page 292: ......
Page 481: ...P A R T 5 Troubleshooting and Maintenance ...
Page 482: ......
Page 531: ...P A R T 6 BPX Specifications ...
Page 532: ......
Page 563: ...P A R T 7 Appendices ...
Page 564: ......