5-9
Cisco Aironet 1570 Series Outdoor Access Point Hardware Installation Guide
OL-32138-01
Chapter 5 Troubleshooting
Using the Reset Button
Monitoring the Power Injector LEDs
You can use the power injector LEDs to check the power injector status. The LEDs provide the following
status information:
•
AP POWER—Turns solid green after successful discovery; indicates that power injector is
supplying power to the access point.
•
FAULT—Turns solid red when a fault occurs during discovery mode or power-up. Check Ethernet
cables and connections before contacting your support organization for assistance.
•
AC POWER—Turns solid green when power injector is receiving AC power and is ready to provide
power to the access point.
Using the Reset Button
The access point has a reset button located on the base (see
), positioned beside
the status LEDs. The reset button is recessed in a small hole that is sealed with a screw and a rubber
gasket.
Resetting the Access Point
The Reset button reboots the access point. To use the Reset button:
Step 1
Use a Phillips screwdriver to remove the reset button screw.
Ensure that your do not to lose the screw and the rubber gasket.
Step 2
To press the Reset button, use a straightened paper-clip or a small screwdriver or a pen.
Step 3
Inspect the gasket. If the gasket has any signs of damage, it should be replaced to avoid water leakage
into the unit.
Step 4
Close the recess with the screw and the gasket. Use a Phillips screwdriver to tighten the screw to
1.8 to 2 lb.ft (2.49 to 2.71 Nm).