2-5
Catalyst 2970 Switch Hardware Installation Guide
OL-6422-01
Chapter 2 Switch Installation
Preparing for Installation
Installation Guidelines
When determining where to place the switch, be sure to observe these
requirements:
•
For 10/100/1000 ports, including 1000BASE-T SFP module ports, cable
lengths from the switch to connected devices are up to 328 feet (100 meters).
•
Table 2-1
lists the cable specifications for 1000BASE-SX, 1000BASE-LX,
and 1000BASE-ZX fiber-optic SFP module connections. Each port must
match the wave-length specifications on the other end of the cable, and the
cable must not exceed the stipulated cable length for reliable
communications.
Table 2-1
Fiber-Optic SFP Module Port Cabling Specifications
SFP Module
Wavelength
(nanometers)
Fiber Type
Core Size
(micron)
Modal
Bandwidth
(MHz/km)
Cable Distance
1000BASE-SX
850
MMF
62.5
62.5
50
50
160
200
400
500
722 feet (220 m)
902 feet (275 m)
1640 feet (500 m)
1804 feet (550 m)
1000BASE-LX/LH
1300
MMF
1
SMF
62.5
50
50
9/10
500
400
500
—
1804 feet (550 m)
1804 feet (550 m)
1804 feet (550 m)
32,810 feet (10 km)
1000BASE-ZX
1550
SMF
9/10
—
43.4 to 62 miles (70
to 100 km)
2
100BASE-FX
Min.: 1270
Typical: 1300
Max.: 1380
MMF
50/125
62.5/125
500
6,562 feet (2 km)
Summary of Contents for 2970 - Catalyst Switch