The connection with a Wave Mode Lock can be
done providing the eSIGNO Mobile in HHI
mode with the Wave Mode Mouse (shown
below), which must be hung up on the Wave
Mode electronic lock.
Thanks to this connection it is possible:
•
to download firmware to the lock;
•
to initialize and synchronize the lock;
•
to manage the lock’s memory (history events,
lock info, settings);
•
to set autoprograms on the lock;
•
to change the lock’s parameters.
HHI
HHI
HHI
HHI
M
M
M
M
ODE
ODE
ODE
ODE
IIII
NTRODUCTION
NTRODUCTION
NTRODUCTION
NTRODUCTION
COMMUNICATION BETWEEN THE HHI AND THE
COMMUNICATION BETWEEN THE HHI AND THE
COMMUNICATION BETWEEN THE HHI AND THE
COMMUNICATION BETWEEN THE HHI AND THE WAVE MODE
WAVE MODE
WAVE MODE
WAVE MODE LOCK
LOCK
LOCK
LOCK
To communicate with a Wave Mode Lock, connect the Wave Mode Mouse to the proper slot on the
eSIGNO Mobile.
After the Wave Mode Mouse has been hung on the Wave Mode Lock, the operator must execute an
HHI command within 10 seconds; otherwise, the Wave Mode Lock turns off itself and communication
can't go on anymore. In this case, it is necessary to remove the Wave Mode Mouse from the mask of
the Wave Mode Lock and re-hang it again to repeat the operation. This procedure is necessary only
for the first command that the HHI has to send to the Wave Mode Lock; when this first command has
been executed correctly (i.e. when the HHI concludes with success the command sent to the lock), it is
not necessary to remove the Wave Mode Mouse from the mask of the lock for another command,
because now HHI has established a continue communication with it: every other command sent from
HHI to the lock will be executed immediately.
Notes
Notes
Notes
Notes: the blinking of the red LED right to the battery one, on the HHI, means that the Wave Mode
Mouse has established a stable communication with the Wave Mode Lock. In this way HHI can
execute several commands, with the Wave Mode Lock answering immediately.
The Wave Mode Lock is normally turned off, waiting for a Wave Mode Card to read.
•
When a Wave Mode Card or the Wave Mode Mouse is placed near the mask of the lock, the
electronic unit of the Wave Mode Lock turns on itself and tries to communicate for 5 seconds.
•
If the lock doesn't recognize a Wave Mode Card within this time period, it then tries to establish
communication with HHI for other 5 seconds.
•
If the lock doesn't recognize a command from the HHI within these last 5 seconds, it turns off itself.
Otherwise, it will execute it and remain turned on, in order to answer to other HHI commands sent
by the operator.
•
When the operator removes the Wave Mode Mouse from the mask of the Wave Mode Lock, the
lock will turn off itself within 5 seconds.
When the communication with the lock has been established, it is possible to use the dedicated short
cut keys to perform several operations.