ESIGNO_SYSTEM_USER_MANUAL_101.DOCX
61/71
N
N
N
N
ETWORKING
ETWORKING
ETWORKING
ETWORKING
H
H
H
H
ARDWARE
ARDWARE
ARDWARE
ARDWARE
((((1
1
1
1))))
TIP
TIP
TIP
TIP
It is possible to configure two sub-networks,
placed in different physical locations, belonging
to the same network and connected through
routers and /or a radio link.
C
C
C
C
ONNECTIONS
ONNECTIONS
ONNECTIONS
ONNECTIONS
SSSS
PECIAL
PECIAL
PECIAL
PECIAL
LLLL
OCKS
OCKS
OCKS
OCKS
The special access
special access
special access
special access control
control
control
control unit
unit
unit
unit allows, coupled with a card reader, to control an access point by using
a standard actuation device (e.g. electric strike, electric or motorized lock). They can be initialized as
standard, common or utility doors. Different access controls like electrical strike doors, elevators or car
parks can be controlled online
online
online
online with the encoding station, allowing access only to the active cards.
Due to the different possible applications and to the hardware used, some of the special lock
parameters have been increased:
•
black list dimension with 80 positions;
•
history of the last 800 operations on the door.
If the special lock is connected online, these added features are available:
•
each time the card is approached to the reader, a real time check on the encoding system is
performed, and the opening is allowed only if the card is still active in the database;
•
all the HHI operations (e.g. history read-out, synchronization) are performed with the HHI directly
connected to the network, without moving to the special access control.
The special lock is composed by one ccccontrol unit
ontrol unit
ontrol unit
ontrol unit and up to two card readers
card readers
card readers
card readers. The control unit has
relay contacts for the output, and the possibility to connect a backup external battery, which can
provide power to it and to the actuation device in case of main power supply loss.
There are two possible work modalities for a special lock:
•
stand
stand
stand
stand----alone
alone
alone
alone: it will work in the same way of a standard CISA lock, with the exception it will activate
a relay. You can initialize the lock with the HHI as you do for a normal CISA CS9500 lock (a special
cable for communication between HHI and the special lock is necessary);
•
on
on
on
on----line
line
line
line: it will work on the same network line of the encoding stations. All the HHI operations are
performed via network from the HHI, selecting on the HHI menu the special lock you want to
connect to instead of moving to the lock itself.
To get the MAC address
MAC address
MAC address
MAC address of a Special Lock #00081, view the sticker underneath the device.