VCC-5CL1R
Rev. 905-0022-02
©2015 CIS Corporation. All rights reserved.
19
7.3.
Horizontal Synchronous Signals Timing (4Tap Medium Configuration Mode: 59fps)
*factory setting
7.4.
Vertical Synchronous Signals Timing (4Tap Medium Configuration Mode: 59fps)
4Taps Configuration Output 59fps mode
FVAL Out
1Frame = 2073H
Effective Line
DVAL Out
LVAL Out
Effective Line
V Blanking
21 or 25H
Exposure Time
SP Out
(Exposure Out)
2
0
4
8
2
0
4
8
1
1
1H = 8.125us
Video Out
Effective Line : 2048H
7~
9H
Effective Line
Invalid
Line
Effective Line
Invalid
Line
□
When a read-out period (FVAL=1) and the exposure start (start-up of Exposure Time) are overlapped, LVAL
and DVAL output Low for approx. 4H, and stop outputting images. In this case, Lo period (V Blanking width)
of FVAL will be shortened by 4H.
□
LVAL of FVAL outputs Lo for approx. 1H at start-up.
□
The delay time between the completion of exposure (The down edge of exposure time) to the start-up of
FVAL includes uncertain delay time less than 1H.