Calculation of Exposure Time
□
The exposure time with manual shutter is to be calculated by 1H width of the output mode shown below and the
value set with the Address 24.
Calculation Formula
:
Exposure Time =1H Width x Value set with the Address 24 +6.67µs
1H width for each mode
2Tap Mode
4Tap Mode
8Tap Mode
10Tap Mode
Horizontal 2560 Pixels
16.125µs 8.125µs 4.125µs 3.4375µs
Horizontal 2048 Pixels
13µs 6.5µs 3.25µs 2.75µs
Horizontal 1920 Pixels
12.125µs 6.125µs 3.0833µs 2.583µs
□
The exposure time with pulse width trigger shutter is to be calculated as follows.
Calculation Formula
:
Exposure Time = Pulse width +6.67µs
The min. trigger pulse width is approx. 3µs.
6.
External Connector Pin Assignment
6.1.
12 pins Circular Connector HR10-10R-12PA (HIROSE) equivalent
Pin No.
Signals
1
GND
2
Power Input (DC+10.8V
~
25V)
3
NA
4
NA
5
GND
6
TRIGGER Input +(isolated)
7
EXPOSURE/FVAL (isolated)
8
GND
9
EXPOSURE/FVAL Output (TTL)
10
TRIGGER Input
−
(isolated)
11
TRIGGER Input (TTL)
12
EXPOSURE/FVAL Output
−
(isolated)