SWITCHING CHARACTERISTICS - CONTROL PORT - SPI FORMAT
Inputs: Logic 0 = DGND = AGND = 0 V, Logic 1 = VLC, C
L
= 30 pF.
14. Data must be held for sufficient time to bridge the transition time of CCLK.
15. For f
sck
<1 MHz.
Parameter
Symbol
Min
Max
Units
CCLK Clock Frequency
f
sck
-
6.0
MHz
RST Rising Edge to CS Falling
t
srs
500
-
ns
CS High Time Between Transmissions
t
csh
1.0
-
s
CS Falling to CCLK Edge
t
css
20
-
ns
CCLK Low Time
t
scl
66
-
ns
CCLK High Time
t
sch
66
-
ns
CDIN to CCLK Rising Setup Time
t
dsu
40
-
ns
CCLK Rising to DATA Hold Time
t
dh
15
-
ns
CCLK Falling to CDOUT Stable
t
pd
-
50
ns
Rise Time of CDOUT
t
r1
-
25
ns
Fall Time of CDOUT
t
f1
-
25
ns
Rise Time of CCLK and CDIN
t
r2
-
100
ns
Fall Time of CCLK and CDIN
t
f2
-
100
ns
t r2
t f2
t dsu
t dh
t sch
t scl
CS
CCLK
CDIN
t css
t pd
CDOUT
tcsh
RST
t srs
Figure 6. Control Port Timing - SPI Format